BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 2

541 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 541 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5541 / 541
EER2 · BTU/Wh11.5–14541 / 541
HSPF2 · BTU/Wh7.8–8.5541 / 541
Cooling capacity · BTU/h22,200–25,000541 / 541
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400541 / 541
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000541 / 541
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500541 / 541
COP at 5°F / −15°C1.9–2.24541 / 541
Equipment / loop typeHP - Split System541 / 541
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)541 / 541
Compressor stagingTwo-stage541 / 541
Connected capabilityNo541 / 541

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA3117XMA*+ furnace: 82*SB48070V17***AHRI reference: 21561631418.008.00111002.10EPA 3946213 →
CVAVA3817XMA*+ furnace: OVMAAB042112AHRI reference: 21561899118.008.00112002.10EPA 3946226 →
CVAVA3117XMA*+ furnace: 82*TB36045V14***AHRI reference: 21561640118.007.80110001.98EPA 3946245 →
CVAVA3117XMA*+ furnace: 986TD42060C17***AHRI reference: 21561655418.007.80112001.96EPA 3946385 →
CVAVA3621XMA*+ furnace: 82*TB66110V21***AHRI reference: 21561736718.007.80108002.00EPA 3946397 →
CAA**2517AM*+ furnace: 83*CA36040C17***AHRI reference: 21564436518.008.50113002.20EPA 3957768 →
CAA**2517AM*+ furnace: 82*SB36070V14***AHRI reference: 21564440418.008.10110002.10EPA 3957792 →
CAA**2517AM*+ furnace: 82*SB48070V17***AHRI reference: 21564442318.008.10111002.10EPA 3957809 →
CAA**2517AM*+ furnace: 83*SB36040M17***AHRI reference: 21564446318.008.10111002.10EPA 3957835 →
CAA**2517AM*+ furnace: 88*TB36070C14***AHRI reference: 21564454018.008.10111002.10EPA 3957886 →
CAA**2517AM*+ furnace: 82*TB36070V14***AHRI reference: 21564462918.008.10110002.10EPA 3957944 →
CAA**3721AM*+ furnace: 82*TB48070V17***AHRI reference: 21564807318.008.10111002.10EPA 3960647 →
CAA**3721AM*+ furnace: 82*TB48090V17***AHRI reference: 21564809718.008.10111002.10EPA 3960653 →
CAA**3721AM*+ furnace: 83*CA36040C17***AHRI reference: 21564775118.008.50113002.20EPA 3960752 →
CAA**3721AM*+ furnace: 82*SB48090V17***AHRI reference: 21564779018.008.10111002.10EPA 3960770 →
CAA**3721AM*+ furnace: 82*SB66110V21***AHRI reference: 21564783018.008.50111002.22EPA 3960868 →
CAA**3721AM*+ furnace: 83*SB36040M17***AHRI reference: 21564784918.008.50111002.24EPA 3960883 →
CAA**3721AM*+ furnace: 83*SB48060M17***AHRI reference: 21564787418.008.50112002.24EPA 3960895 →
CAA**3721AM*+ furnace: 83*SB60080M21***AHRI reference: 21564789818.008.50111002.24EPA 3960918 →
CAA**3721AM*+ furnace: 88*TB48070C17***AHRI reference: 21564797218.008.10111002.10EPA 3961027 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →