BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 2

541 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 541 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5541 / 541
EER2 · BTU/Wh11.5–14541 / 541
HSPF2 · BTU/Wh7.8–8.5541 / 541
Cooling capacity · BTU/h22,200–25,000541 / 541
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400541 / 541
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000541 / 541
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500541 / 541
COP at 5°F / −15°C1.9–2.24541 / 541
Equipment / loop typeHP - Split System541 / 541
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)541 / 541
Compressor stagingTwo-stage541 / 541
Connected capabilityNo541 / 541

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA3117XMA*+ furnace: 82*SB48070V17***AHRI reference: 21561631418.008.00111002.10EPA 3946213
CVAVA3817XMA*+ furnace: OVMAAB042112AHRI reference: 21561899118.008.00112002.10EPA 3946226
CVAVA3117XMA*+ furnace: 82*TB36045V14***AHRI reference: 21561640118.007.80110001.98EPA 3946245
CVAVA3117XMA*+ furnace: 986TD42060C17***AHRI reference: 21561655418.007.80112001.96EPA 3946385
CVAVA3621XMA*+ furnace: 82*TB66110V21***AHRI reference: 21561736718.007.80108002.00EPA 3946397
CAA**2517AM*+ furnace: 83*CA36040C17***AHRI reference: 21564436518.008.50113002.20EPA 3957768
CAA**2517AM*+ furnace: 82*SB36070V14***AHRI reference: 21564440418.008.10110002.10EPA 3957792
CAA**2517AM*+ furnace: 82*SB48070V17***AHRI reference: 21564442318.008.10111002.10EPA 3957809
CAA**2517AM*+ furnace: 83*SB36040M17***AHRI reference: 21564446318.008.10111002.10EPA 3957835
CAA**2517AM*+ furnace: 88*TB36070C14***AHRI reference: 21564454018.008.10111002.10EPA 3957886
CAA**2517AM*+ furnace: 82*TB36070V14***AHRI reference: 21564462918.008.10110002.10EPA 3957944
CAA**3721AM*+ furnace: 82*TB48070V17***AHRI reference: 21564807318.008.10111002.10EPA 3960647
CAA**3721AM*+ furnace: 82*TB48090V17***AHRI reference: 21564809718.008.10111002.10EPA 3960653
CAA**3721AM*+ furnace: 83*CA36040C17***AHRI reference: 21564775118.008.50113002.20EPA 3960752
CAA**3721AM*+ furnace: 82*SB48090V17***AHRI reference: 21564779018.008.10111002.10EPA 3960770
CAA**3721AM*+ furnace: 82*SB66110V21***AHRI reference: 21564783018.008.50111002.22EPA 3960868
CAA**3721AM*+ furnace: 83*SB36040M17***AHRI reference: 21564784918.008.50111002.24EPA 3960883
CAA**3721AM*+ furnace: 83*SB48060M17***AHRI reference: 21564787418.008.50112002.24EPA 3960895
CAA**3721AM*+ furnace: 83*SB60080M21***AHRI reference: 21564789818.008.50111002.24EPA 3960918
CAA**3721AM*+ furnace: 88*TB48070C17***AHRI reference: 21564797218.008.10111002.10EPA 3961027