BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN524**AA*

2-STAGE 18 SEER HP

541 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 541 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5541 / 541
EER2 · BTU/Wh11.5–14541 / 541
HSPF2 · BTU/Wh7.8–8.5541 / 541
Cooling capacity · BTU/h22,200–25,000541 / 541
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400541 / 541
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000541 / 541
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500541 / 541
COP at 5°F / −15°C1.9–2.24541 / 541
Equipment / loop typeHP - Split System541 / 541
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)541 / 541
Compressor stagingTwo-stage541 / 541
Connected capabilityNo541 / 541

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA3817XMA*+ furnace: 83*CA36040C17***AHRI reference: 21561861018.507.80110001.98EPA 3946070
CVAMA3217XMA*+ furnace: 83*CA36040C17***AHRI reference: 21561434818.507.80110001.98EPA 3946143
CVAMA3217XMA*+ furnace: 82*SB36070V14***AHRI reference: 21561437518.507.80109002.00EPA 3946165
CVAMA3217XMA*+ furnace: 83*SB36040M17***AHRI reference: 21561441418.507.80108002.00EPA 3946188
CVAMA3217XMA*+ furnace: 82*TB36070V14***AHRI reference: 21561452618.507.80109002.00EPA 3946304
CVAVA3621XMA*+ furnace: 926TC60080V21***AHRI reference: 21561773518.007.80108002.00EPA 3945921
CVAVA3721XMA*+ furnace: 82*SB48070V17***AHRI reference: 21561785418.007.80109001.98EPA 3945939
CVAVA3721XMA*+ furnace: 83*SB60100M21***AHRI reference: 21561796318.007.80109001.98EPA 3945955
CVAVA3721XMA*+ furnace: 88*TB48090C17***AHRI reference: 21561802418.007.80108001.98EPA 3945972
CVAVA3721XMA*+ furnace: 987MC60080C21***AHRI reference: 21561821018.007.80108002.00EPA 3945986
CVAMA3117XMA*+ furnace: 935CB48060C17***AHRI reference: 21561402718.007.80110001.98EPA 3946004
CVAVA3721XMA*+ furnace: 987MC66100C21***AHRI reference: 21561822418.007.80108002.00EPA 3946021
CVAVA3721XMA*+ furnace: 986TD42080C17***AHRI reference: 21561840718.007.80109001.98EPA 3946036
CVAVA3721XMA*+ furnace: 926TC60080V21***AHRI reference: 21561850518.007.80109002.00EPA 3946051
CVAVA3817XMA*+ furnace: 926SB48060V17***AHRI reference: 21561883118.007.80111001.96EPA 3946087
CVAMA3117XMA*+ furnace: 926SB48060V17***AHRI reference: 21561410818.007.80111001.96EPA 3946097
CVAMA3217XMA*+ furnace: 986TD42060C17***AHRI reference: 21561472118.007.80108001.98EPA 3946114
CVAMA3117XMA*+ furnace: 926TC48060V17***AHRI reference: 21561426818.007.80111001.96EPA 3946120
CVAVA3117XMA*+ furnace: 82*SB36045V14***AHRI reference: 21561628818.007.80110001.98EPA 3946154
CVAVA3817XMA*+ furnace: 926TC48060V17***AHRI reference: 21561894518.007.80111001.96EPA 3946200

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →