BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH5SAN536**AA*

15 SEER2 HP

33 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity33,800–36,800BTU/h

Each efficiency range summarizes published EPA records for PH5SAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 33 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1633 / 33
EER2 · BTU/Wh11.7–1333 / 33
HSPF2 · BTU/Wh7.8–833 / 33
Cooling capacity · BTU/h33,800–36,80033 / 33
Heating capacity at 47°F / 8.3°C · BTU/h33,200–36,40033 / 33
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,80033 / 33
Heating capacity at 5°F / −15°C · BTU/h16,100–18,10033 / 33
COP at 5°F / −15°C2–2.2233 / 33
Equipment / loop typeHP - Split System33 / 33
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)33 / 33
Compressor stagingSingle stage33 / 33
Connected capabilityNo33 / 33

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FEVA0048**+NAVA54801CKAHRI reference: 21705163716.008.00174002.18EPA 4001106
FT5AN(B,X)C48L*AHRI reference: 21417993515.507.80167002.18EPA 3404457
FG5ANXC48L*AHRI reference: 21417993615.507.80167002.18EPA 3404459
PF5TNXC48L*AHRI reference: 21417993715.507.80167002.18EPA 3404460
PF5MN*C48L*AHRI reference: 21418017815.507.80174002.18EPA 3404794
FJ5AN*C48L*AHRI reference: 21418017715.507.80174002.18EPA 3404796
FEVB0048**+NAVA54801CKAHRI reference: 21427759715.507.80174002.22EPA 3415686
FMA5X36**AL*AHRI reference: 21442428915.507.80170002.00EPA 3425165
F55AA*C48L*AHRI reference: 21646400115.507.80174002.18EPA 3846922
CAA**4821AM*+ furnace: 83*SB48060M17***AHRI reference: 21414163115.207.80176002.18EPA 3400337
CAA**4821AM*+ furnace: 935SB66100M21***AHRI reference: 21414263415.207.80176002.18EPA 3400439
CAA**4821AM*+ furnace: 88*TB60110C21***AHRI reference: 21414183515.207.80175002.18EPA 3400471
CAA**4821AM*+ furnace: 82*TB60090V21***AHRI reference: 21414194415.207.80175002.18EPA 3400611
CAA**4821AM*+ furnace: 926TC66100V21***AHRI reference: 21414286015.207.80175002.20EPA 3400665
CAA**4821AM*+ furnace: 8(0,1)*SB60090M21***AHRI reference: 21414133915.207.80175002.18EPA 3400765
CAA**4321AM*+ furnace: 912SE60100M21***AHRI reference: 21414051215.207.80179002.20EPA 3400787
CAA**4821AM*+ furnace: 8(0,1)*SB60110M21***AHRI reference: 21414136915.207.80176002.20EPA 3400839
CAA**4821AM*+ furnace: 912SE60100M21***AHRI reference: 21414225815.207.80176002.18EPA 3400870
CAA**4821AM*+ furnace: 82*SB60090V21***AHRI reference: 21414145315.207.80175002.18EPA 3400919
CVAMA4421XMA*+ furnace: 83*SA36040E17***AHRI reference: 21414304715.207.80181002.14EPA 3401011

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →