BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH5SAN536**AA*

15 SEER2 HP · EPA record 3400919

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3400919. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh15.20
EER2 · BTU/Wh12.00
HSPF2 · BTU/Wh7.80
Cooling capacity · BTU/h34400
Heating capacity at 47°F / 8.3°C · BTU/h33800
Heating capacity at 17°F / −8.3°C · BTU/h22000
Heating capacity at 5°F / −15°C · BTU/h17500
COP at 5°F / −15°C2.18
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingSingle stage
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitPH5SAN536**AA*
+
Indoor unitCAA**4821AM*
+
Required furnace82*SB60090V21***

AHRI reference 214141453 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for PH5SAN536**AA*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3400919EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.18EPA Sep 21, 2026
eer2 btu wh12.00EPA Sep 21, 2026
series name15 SEER2 HPEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh7.80EPA Sep 21, 2026
model numberPH5SAN536**AA*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh15.20EPA Sep 21, 2026
date certified2025-07-03T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingSingle stageEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number82*SB60090V21***EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number214141453EPA Sep 21, 2026
cooling capacity btu h34400EPA Sep 21, 2026
outdoor unit brand nameBRYANT HEATING AND COOLING SYSTEMSEPA Sep 21, 2026
date available on market2024-01-01T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCAA**4821AM*EPA Sep 21, 2026
energy star model identifierES_1020846_PH5SAN536**AA*_02022024013545_7092465EPA Sep 21, 2026
heating capacity at 5 f btu h17500EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h22000EPA Sep 21, 2026
heating capacity at 47 f btu h33800EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testNoneEPA Sep 21, 2026