BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH5SAN518**AA*

15 SEER2 HP · source records, page 2

50 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,400–18,900BTU/h

Each efficiency range summarizes published EPA records for PH5SAN518**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 50 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.550 / 50
EER2 · BTU/Wh11.7–12.550 / 50
HSPF2 · BTU/Wh7.8–850 / 50
Cooling capacity · BTU/h17,400–18,90050 / 50
Heating capacity at 47°F / 8.3°C · BTU/h16,400–18,30050 / 50
Heating capacity at 17°F / −8.3°C · BTU/h10,500–11,00050 / 50
Heating capacity at 5°F / −15°C · BTU/h8,200–8,60050 / 50
COP at 5°F / −15°C1.88–2.150 / 50
Equipment / loop typeHP - Split System50 / 50
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)50 / 50
Compressor stagingSingle stage50 / 50
Connected capabilityNo50 / 50

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**2517AM*+ furnace: 83*SB48060M17***AHRI reference: 21412649515.207.8084002.06EPA 3399089
CAA**2517AM*+ furnace: 916SA48080M17***AHRI reference: 21412708015.207.8085002.04EPA 3399098
CAA**1917AM*+ furnace: 935SB48060M17***AHRI reference: 21412576115.207.8084002.04EPA 3399130
CAA**2517AM*+ furnace: 88*TB36070C14***AHRI reference: 21412655415.207.8084002.06EPA 3399176
CAA**2517AM*+ furnace: 935SB48060M17***AHRI reference: 21412718915.207.8085002.04EPA 3399201
CAA**1917AM*+ furnace: 82*SB48070V17***AHRI reference: 21412499815.207.8084002.04EPA 3399233
CAA**1917AM*+ furnace: 83*SA36040E17***AHRI reference: 21412502315.207.8083002.04EPA 3399258
CAA**1917AM*+ furnace: 986TD42080C17***AHRI reference: 21412581815.207.8084002.02EPA 3399306
CAA**2517AM*+ furnace: 986TD42080C17***AHRI reference: 21412724815.207.8084002.04EPA 3399333
CAA**2517AM*+ furnace: 926TC48060V17***AHRI reference: 21412733615.207.8084002.04EPA 3399363
CAA**1917AM*+ furnace: 83*SB36040M17***AHRI reference: 21412508315.207.8084002.04EPA 3399427
CAA**1917AM*+ furnace: 83*SB48060M17***AHRI reference: 21412511315.207.8084002.04EPA 3399457
CAA**1917AM*+ furnace: 88*TB36070C14***AHRI reference: 21412519715.207.8084002.04EPA 3399482
CAA**1917AM*+ furnace: 88*TB48090C17***AHRI reference: 21412525115.207.8084002.02EPA 3399511
CAA**2517AM*+ furnace: 912SE42060M17***AHRI reference: 21412698415.207.8084002.04EPA 3399711
CAA**2517AM*+ furnace: 88*TB48070C17***AHRI reference: 21412658115.207.8085002.04EPA 3399725
CAA**2517AM*+ furnace: 88*TB48090C17***AHRI reference: 21412660815.207.8085002.04EPA 3399752
CAA**2517AM*+ furnace: 82*SB36045V14***AHRI reference: 21412629915.207.8084002.04EPA 3399779
CAA**2517AM*+ furnace: 82*SB48070V17***AHRI reference: 21412634915.207.8084002.04EPA 3399803
CAA**1917AM*+ furnace: 82*SB36045V14***AHRI reference: 21412494815.207.8084002.04EPA 3399817

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →