BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH5SAN518**AA*

15 SEER2 HP

50 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,400–18,900BTU/h

Each efficiency range summarizes published EPA records for PH5SAN518**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 50 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.550 / 50
EER2 · BTU/Wh11.7–12.550 / 50
HSPF2 · BTU/Wh7.8–850 / 50
Cooling capacity · BTU/h17,400–18,90050 / 50
Heating capacity at 47°F / 8.3°C · BTU/h16,400–18,30050 / 50
Heating capacity at 17°F / −8.3°C · BTU/h10,500–11,00050 / 50
Heating capacity at 5°F / −15°C · BTU/h8,200–8,60050 / 50
COP at 5°F / −15°C1.88–2.150 / 50
Equipment / loop typeHP - Split System50 / 50
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)50 / 50
Compressor stagingSingle stage50 / 50
Connected capabilityNo50 / 50

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA3217XMA*+ furnace: 8(0,1)*SB36070M17***AHRI reference: 21419543815.507.8082001.94EPA 3406122 →
CVAMA3217XMA*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 21419546815.507.8082001.94EPA 3406154 →
FMA5X24**AL*AHRI reference: 21442392115.508.0082002.10EPA 3425244 →
CAA**2517AM*+ furnace: 82*TB36045V14***AHRI reference: 21412667515.207.8084002.04EPA 3398524 →
CAA**1917AM*+ furnace: 8(0,1)*SB36045M14***AHRI reference: 21412477315.207.8084002.02EPA 3398527 →
CAA**1917AM*+ furnace: 8(0,1)*SB36070M14***AHRI reference: 21412480315.207.8084002.04EPA 3398557 →
CAA**1917AM*+ furnace: 8(0,1)*SB36070M17***AHRI reference: 21412483315.207.8083002.04EPA 3398588 →
CAA**2517AM*+ furnace: 8(0,1)*SB36045M14***AHRI reference: 21412608615.207.8084002.04EPA 3398616 →
CAA**2517AM*+ furnace: 82*TB36070V14***AHRI reference: 21412670515.207.8084002.06EPA 3398669 →
CAA**1917AM*+ furnace: 82*TB36070V14***AHRI reference: 21412531615.207.8084002.04EPA 3398694 →
CAA**2517AM*+ furnace: 8(0,1)*SB36070M14***AHRI reference: 21412614615.207.8084002.06EPA 3398703 →
CAA**2517AM*+ furnace: 8(0,1)*SB36070M17***AHRI reference: 21412617815.207.8084002.06EPA 3398735 →
CAA**2517AM*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 21412620815.207.8085002.06EPA 3398765 →
CAA**2517AM*+ furnace: 82*TB48070V17***AHRI reference: 21412671715.207.8085002.04EPA 3398770 →
CAA**2517AM*+ furnace: 8(0,1)*SB42090M17***AHRI reference: 21412624015.207.8084002.04EPA 3398819 →
CAA**1917AM*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 21412486115.207.8084002.04EPA 3398861 →
CAA**1917AM*+ furnace: 8(0,1)*SB42090M17***AHRI reference: 21412489115.207.8084002.04EPA 3398897 →
CAA**2517AM*+ furnace: 912SE48080M17***AHRI reference: 21412701615.207.8084002.06EPA 3398943 →
CAA**2517AM*+ furnace: 83*SA36040E17***AHRI reference: 21412639915.207.8084002.06EPA 3398993 →
CAA**2517AM*+ furnace: 83*SB36040M17***AHRI reference: 21412646315.207.8084002.06EPA 3399072 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →