37MUHAQ36AA3+KSAIC0701230
Crossover Heat Pump · source records, page 2
338 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 37MUHAQ36AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 338 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 338 / 338 |
| EER2 · BTU/Wh | 9.4–10.5 | 338 / 338 |
| HSPF2 · BTU/Wh | 8.1–9 | 338 / 338 |
| Cooling capacity · BTU/h | 34,200–38,000 | 338 / 338 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–40,000 | 338 / 338 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,400–26,200 | 338 / 338 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–31,600 | 338 / 338 |
| COP at 5°F / −15°C | 1.75–1.9 | 338 / 338 |
| Equipment / loop type | HP - Split System | 338 / 338 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 338 / 338 |
| Compressor staging | Continuously variable | 338 / 338 |
| Connected capability | No | 338 / 338 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**4321AM*+ furnace: 83*SB60100M21***Cold climate designationAHRI reference: 218479955 | 16.50 | 8.50 | 30400 | 1.84 | EPA 4628294 → |
CAA**4321AM*+ furnace: 83*SB60080M21***Cold climate designationAHRI reference: 218479951 | 16.50 | 8.50 | 30200 | 1.86 | EPA 4628296 → |
CAA**4321AM*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 218479947 | 16.50 | 8.50 | 30200 | 1.84 | EPA 4628298 → |
CAA**4321AM*+ furnace: 83*SB36040M17***Cold climate designationAHRI reference: 218479943 | 16.50 | 8.50 | 30200 | 1.84 | EPA 4628300 → |
CAA**4321AM*+ furnace: 82*SB66110V21***Cold climate designationAHRI reference: 218479941 | 16.50 | 8.50 | 30200 | 1.84 | EPA 4628301 → |
CAA**4321AM*+ furnace: 82*SB60090V21***Cold climate designationAHRI reference: 218479939 | 16.50 | 8.50 | 30400 | 1.86 | EPA 4628302 → |
CAA**4821AM*+ furnace: 927TA66100V21***Cold climate designationAHRI reference: 218479925 | 16.50 | 8.10 | 30000 | 1.75 | EPA 4628306 → |
CAA**4821AM*+ furnace: 927TA60080V21***Cold climate designationAHRI reference: 218479917 | 16.50 | 8.50 | 30200 | 1.84 | EPA 4628310 → |
CAA**4821AM*+ furnace: 926TC66100V21***Cold climate designationAHRI reference: 218479908 | 16.50 | 8.10 | 30000 | 1.75 | EPA 4628315 → |
CAA**4821AM*+ furnace: 926TC60080V21***Cold climate designationAHRI reference: 218479898 | 16.50 | 8.50 | 30200 | 1.84 | EPA 4628320 → |
CAA**4821AM*+ furnace: 935SB66100M21***Cold climate designationAHRI reference: 218479881 | 16.50 | 8.50 | 30000 | 1.84 | EPA 4628327 → |
CAA**4821AM*+ furnace: 935SB60100M21***Cold climate designationAHRI reference: 218479877 | 16.50 | 8.50 | 30200 | 1.84 | EPA 4628329 → |
CAA**4821AM*+ furnace: 926SB60080V21***Cold climate designationAHRI reference: 218479861 | 16.50 | 8.50 | 30200 | 1.84 | EPA 4628337 → |
CAA**4821AM*+ furnace: 82*TB66110V21***Cold climate designationAHRI reference: 218479851 | 16.50 | 8.50 | 30200 | 1.84 | EPA 4628341 → |
CAA**4821AM*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 218479826 | 16.50 | 8.50 | 30000 | 1.84 | EPA 4628353 → |
CAA**4821AM*+ furnace: 82*SB66110V21***Cold climate designationAHRI reference: 218479821 | 16.50 | 8.50 | 30200 | 1.84 | EPA 4628356 → |
FG5ANXC36L*Cold climate designationAHRI reference: 218479375 | 16.50 | 8.50 | 31000 | 1.76 | EPA 4628507 → |
PF5TNXC36L*Cold climate designationAHRI reference: 218479366 | 16.50 | 8.50 | 31000 | 1.76 | EPA 4628512 → |
CAA**4821AM*+ furnace: 8(0,1)*SB60110M21***Cold climate designationAHRI reference: 218480758 | 16.00 | 8.50 | 30000 | 1.82 | EPA 4628002 → |
CAA**4321AM*+ furnace: 8(0,1)*SB60110M21***Cold climate designationAHRI reference: 218480754 | 16.00 | 8.50 | 30200 | 1.84 | EPA 4628004 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →