293VAN024**AA*
Evolution 23 VS Heat Pump · source records, page 6
430 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 293VAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–23 | 430 / 430 |
| EER2 · BTU/Wh | 10.5–14 | 430 / 430 |
| HSPF2 · BTU/Wh | 8.5–10.5 | 430 / 430 |
| Cooling capacity · BTU/h | 21,600–23,800 | 430 / 430 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,800–28,200 | 430 / 430 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,000–26,400 | 430 / 430 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,100–23,000 | 430 / 430 |
| COP at 5°F / −15°C | 1.84–2.1 | 430 / 430 |
| Equipment / loop type | HP - Split System | 430 / 430 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 430 / 430 |
| Compressor staging | Continuously variable | 430 / 430 |
| Connected capability | No | 430 / 430 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA3017XMA*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 217624838 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499348 → |
CVAVA3617XMA*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 217624842 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499352 → |
CVAVA3621XMA*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 217624844 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499353 → |
CVAMA3017XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217624966 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499354 → |
CVAVA3721XMA*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 217624846 | 21.50 | 9.50 | 22400 | 2.06 | EPA 4499358 → |
CVAVA4217XMA*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 217624850 | 21.50 | 9.50 | 22400 | 2.08 | EPA 4499362 → |
CVAVA4221XMA*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 217624852 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499364 → |
CVAMA3617XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217624972 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499373 → |
CVAMA4221XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217624974 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499374 → |
CVAVA2517XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217624982 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499382 → |
CVAVA3617XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217624988 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499387 → |
CVAVA3017XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217624984 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499388 → |
CVAVA3621XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217624990 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499390 → |
CVAVA4217XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217624996 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499397 → |
CVAVA4221XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217624998 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499398 → |
CVAMA2517XMA*+UI+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 217625002 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499401 → |
CVAMA3017XMA*+UI+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 217625004 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499404 → |
CVAMA4221XMA*+UI+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 217625010 | 21.50 | 9.00 | 22200 | 1.98 | EPA 4499465 → |
CVAVA2517XMA*+UI+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 217625018 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499474 → |
CVAVA3017XMA*+UI+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 217625020 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499475 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →