BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

293VAN024**AA*

Evolution 23 VS Heat Pump · source records, page 5

430 published source records · source checked Sep 21, 2026

SEER2 range18–23BTU/Wh
HSPF2 range8.5–10.5BTU/Wh
Cooling capacity21,600–23,800BTU/h

Each efficiency range summarizes published EPA records for 293VAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–23430 / 430
EER2 · BTU/Wh10.5–14430 / 430
HSPF2 · BTU/Wh8.5–10.5430 / 430
Cooling capacity · BTU/h21,600–23,800430 / 430
Heating capacity at 47°F / 8.3°C · BTU/h24,800–28,200430 / 430
Heating capacity at 17°F / −8.3°C · BTU/h24,000–26,400430 / 430
Heating capacity at 5°F / −15°C · BTU/h19,100–23,000430 / 430
COP at 5°F / −15°C1.84–2.1430 / 430
Equipment / loop typeHP - Split System430 / 430
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)430 / 430
Compressor stagingContinuously variable430 / 430
Connected capabilityNo430 / 430

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA4217XMA*+UI+ furnace: 88*TB36070C14***Cold climate designationAHRI reference: 21762474022.009.50224002.08EPA 4499843
CVAMA3117XMA*+UI+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 21762474822.009.50224002.08EPA 4499851
CVAMA4321XMA*+UI+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 21762475622.009.50224002.06EPA 4499859
CVAVA3117XMA*+UI+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 21762476622.009.50224002.08EPA 4499869
CVAVA3721XMA*+UI+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 21762477222.009.50224002.06EPA 4499875
CVAVA3817XMA*+UI+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 21762477422.009.50224002.06EPA 4499877
CVAMA4221XMA*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 21762479222.009.50222002.08EPA 4499895
CVAMA4321XMA*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 21762479422.009.50224002.08EPA 4499897
CVAVA3621XMA*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 21762480822.009.50222002.08EPA 4499911
CVAVA3721XMA*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 21762481022.009.50224002.08EPA 4499913
CVAVA4221XMA*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 21762481622.009.50222002.08EPA 4499917
CVAVA4217XMA*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 21762481422.009.50224002.08EPA 4499920
CVAMA3117XMA*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 21762482422.009.50224002.06EPA 4499927
CVAMA3217XMA*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 21762482622.009.50224002.06EPA 4499929
CVAMA3117XMA*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 21762489822.009.50224002.06EPA 4499945
CVAMA4321XMA*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 21762490622.009.50224002.06EPA 4499952
CVAVA3117XMA*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 21762491422.009.50224002.06EPA 4499961
CVAVA3721XMA*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 21762492022.009.50224002.06EPA 4499967
FE5BN(B,X)C36L*+UICold climate designationAHRI reference: 21762425321.5010.50195002.06EPA 4499161
CVAMA2517XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 21762496421.509.00224001.98EPA 4499342

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.