249VAN048**AA*
Preferred 19 SEER2 VS HP · source records, page 3
517 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 249VAN048**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 517 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 517 / 517 |
| EER2 · BTU/Wh | 10–13.5 | 517 / 517 |
| HSPF2 · BTU/Wh | 8.5–10 | 517 / 517 |
| Cooling capacity · BTU/h | 43,500–49,500 | 517 / 517 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 517 / 517 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 517 / 517 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 517 / 517 |
| COP at 5°F / −15°C | 1.95–2.32 | 517 / 517 |
| Equipment / loop type | HP - Split System | 517 / 517 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 517 / 517 |
| Compressor staging | Continuously variable | 517 / 517 |
| Connected capability | No | 517 / 517 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA4821XMA*+ furnace: 83*CB60080C21***Cold climate designationAHRI reference: 217916241 | 16.50 | 9.00 | 39500 | 2.10 | EPA 4530939 → |
CVAVA4821XMA*+ furnace: 83*SB60080M21***Cold climate designationAHRI reference: 217916293 | 16.50 | 9.00 | 39500 | 2.10 | EPA 4531070 → |
CVAVA4924XMA*+ furnace: 83*SB60080M21***Cold climate designationAHRI reference: 217916684 | 16.50 | 9.00 | 40000 | 2.10 | EPA 4531469 → |
CVAMA6021XMA*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 217915850 | 16.50 | 9.00 | 40500 | 2.10 | EPA 4531857 → |
CVAMA6021XMA*+ furnace: 83*SB60080M21***Cold climate designationAHRI reference: 217915863 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4531921 → |
CVAMA6021XMA*+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 217915915 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4531945 → |
CVAMA4921XMA*+ furnace: 82*SB66110V21***Cold climate designationAHRI reference: 217915407 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4532209 → |
CVAMA4921XMA*+ furnace: 83*SB60100M21***Cold climate designationAHRI reference: 217915446 | 16.50 | 9.00 | 40500 | 2.10 | EPA 4533168 → |
CVAMA4921XMA*+ furnace: 83*SB60080M21***Cold climate designationAHRI reference: 217915433 | 16.50 | 9.00 | 40000 | 2.15 | EPA 4533185 → |
CVAMA6021XMA*+ furnace: 82*TB60090V21***Cold climate designationAHRI reference: 217915928 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4533496 → |
CVAMA6021XMA*+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 217915967 | 16.50 | 9.00 | 40000 | 2.15 | EPA 4534817 → |
CVAMA4921XMA*+ furnace: 935SB66100M21***Cold climate designationAHRI reference: 217915641 | 16.50 | 9.00 | 40500 | 2.10 | EPA 4535153 → |
CVAMA6021XMA*+ furnace: 935SB66100M21***Cold climate designationAHRI reference: 217916071 | 16.50 | 9.00 | 40000 | 2.10 | EPA 4535307 → |
CVAMA4921XMA*+ furnace: 83*CB60080C21***Cold climate designationAHRI reference: 217915368 | 16.50 | 9.00 | 40500 | 2.15 | EPA 4535550 → |
CVAMA6021XMA*+ furnace: 83*CB60080C21***Cold climate designationAHRI reference: 217915798 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4535734 → |
CVAMA6021XMA*+ furnace: 82*SB60090V21***Cold climate designationAHRI reference: 217915824 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4535761 → |
CVAMA6021XMA*+ furnace: 82*SB66110V21***Cold climate designationAHRI reference: 217915837 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4535775 → |
CVAMA4921XMA*+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 217915472 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4536271 → |
CVAMA4921XMA*+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 217915485 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4536282 → |
CVAVA6021XMA*+ furnace: 82*SB60090V21***Cold climate designationAHRI reference: 217916985 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4536296 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →