BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

249VAN036**AA*

Preferred 19 SEER2 VS HP · source records, page 6

476 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity33,400–37,600BTU/h

Each efficiency range summarizes published EPA records for 249VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 476 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18476 / 476
EER2 · BTU/Wh10.5–13.5476 / 476
HSPF2 · BTU/Wh7.8–9476 / 476
Cooling capacity · BTU/h33,400–37,600476 / 476
Heating capacity at 47°F / 8.3°C · BTU/h31,800–37,400476 / 476
Heating capacity at 17°F / −8.3°C · BTU/h25,200–37,600476 / 476
Heating capacity at 5°F / −15°C · BTU/h24,600–26,600476 / 476
COP at 5°F / −15°C1.9–2.18476 / 476
Equipment / loop typeHP - Split System476 / 476
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)476 / 476
Compressor stagingContinuously variable476 / 476
Connected capabilityNo476 / 476

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA4321XMA*+ furnace: 88*TB60070C21***Cold climate designationAHRI reference: 21790962916.008.50248002.05EPA 4536165
CVAMA4321XMA*+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 21790964416.008.50248002.05EPA 4536179
CVAMA4321XMA*+ furnace: 927TA48080V17***Cold climate designationAHRI reference: 21791021816.008.50248002.05EPA 4536212
CVAMA4321XMA*+ furnace: 927TA60080V21***Cold climate designationAHRI reference: 21791023316.008.50248002.05EPA 4536237
CAA**4821AM*+ furnace: 83*SB60080M21***AHRI reference: 21792555216.009.00250002.06EPA 4536335
CAA**4821AM*+ furnace: 82*SB60090V21***AHRI reference: 21792549216.009.00252002.04EPA 4536765
CAA**4321AM*+ furnace: 83*SB60080M21***AHRI reference: 21792471116.009.00246002.05EPA 4537910
CAA**4821AM*+ furnace: 82*TB60090V21***AHRI reference: 21792568816.009.00252002.04EPA 4539377
CAA**4321AM*+ furnace: 83*CB60080C21***AHRI reference: 21792459116.009.00246002.06EPA 4540770
CAA**4821AM*+ furnace: 83*CB60080C21***AHRI reference: 21792543216.009.00250002.06EPA 4541815
CAA**4821AM*+ furnace: 926TC66100V21***AHRI reference: 21792615316.009.00250002.04EPA 4542612
CAA**4821AM*+ furnace: 927TA66100V21***AHRI reference: 21792622816.009.00250002.04EPA 4543088
CVAVA3817XMA*+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 21791278815.508.50266002.00EPA 4529907
CVAMA4921XMA*+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 21791091215.508.50264002.00EPA 4529957
CVAVA4221XMA*+ furnace: 927TA60080V21***Cold climate designationAHRI reference: 21791404515.508.50264002.00EPA 4530183
CVAVA4821XMA*+ furnace: 83*CB60080C21***Cold climate designationAHRI reference: 21791413515.508.50260002.00EPA 4530316
CVAMA4321XMA*+ furnace: 935SB36040M17***Cold climate designationAHRI reference: 21790991515.508.50252002.04EPA 4530548
CVAVA3617XMA*+ furnace: 83*CB36040C17***AHRI reference: 21791109515.507.80258002.05EPA 4530613
CVAVA3617XMA*+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 21791139715.508.50260002.02EPA 4530771
CVAVA4221XMA*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 21791360615.508.50262002.00EPA 4530908