249VAN036**AA*
Preferred 19 SEER2 VS HP · source records, page 5
476 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 249VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 476 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 476 / 476 |
| EER2 · BTU/Wh | 10.5–13.5 | 476 / 476 |
| HSPF2 · BTU/Wh | 7.8–9 | 476 / 476 |
| Cooling capacity · BTU/h | 33,400–37,600 | 476 / 476 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,800–37,400 | 476 / 476 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–37,600 | 476 / 476 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–26,600 | 476 / 476 |
| COP at 5°F / −15°C | 1.9–2.18 | 476 / 476 |
| Equipment / loop type | HP - Split System | 476 / 476 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 476 / 476 |
| Compressor staging | Continuously variable | 476 / 476 |
| Connected capability | No | 476 / 476 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAMA4321XMA*+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 217909750 | 16.00 | 8.80 | 25000 | 2.10 | EPA 4534963 → |
CVAVA4221XMA*+ furnace: 926TC66100V21***Cold climate designationAHRI reference: 217914000 | 16.00 | 9.00 | 26000 | 2.14 | EPA 4535048 → |
CVAVA3721XMA*+ furnace: 82*SB66110V21***Cold climate designationAHRI reference: 217912289 | 16.00 | 9.00 | 26200 | 2.14 | EPA 4535081 → |
CVAMA4821XMA*+ furnace: 927TA66100V21***Cold climate designationAHRI reference: 217910852 | 16.00 | 9.00 | 26200 | 2.12 | EPA 4535103 → |
CVAMA4921XMA*+ furnace: 82*SB48090V17***Cold climate designationAHRI reference: 217910882 | 16.00 | 9.00 | 26400 | 2.12 | EPA 4535188 → |
CVAMA4321XMA*+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 217909419 | 16.00 | 8.50 | 25000 | 2.05 | EPA 4535350 → |
CVAMA4321XMA*+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217909990 | 16.00 | 8.50 | 25000 | 2.05 | EPA 4535437 → |
CVAMA4321XMA*+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 217910020 | 16.00 | 8.50 | 24800 | 2.05 | EPA 4535476 → |
CVAMA4321XMA*+ furnace: 986TD66100C21***Cold climate designationAHRI reference: 217910035 | 16.00 | 8.50 | 24800 | 2.05 | EPA 4535490 → |
CVAVA3817XMA*+ furnace: 926TC48080V17***Cold climate designationAHRI reference: 217913017 | 16.00 | 9.00 | 26400 | 2.12 | EPA 4535568 → |
CVAMA4321XMA*+ furnace: 927TA60100V21***Cold climate designationAHRI reference: 217910248 | 16.00 | 8.50 | 25000 | 2.05 | EPA 4535586 → |
CVAMA4321XMA*+ furnace: 927TA66100V21***Cold climate designationAHRI reference: 217910263 | 16.00 | 8.50 | 24800 | 2.05 | EPA 4535656 → |
CVAVA3621XMA*+ furnace: 83*SB60080M21***Cold climate designationAHRI reference: 217911654 | 16.00 | 8.50 | 26000 | 2.00 | EPA 4535662 → |
CVAVA3817XMA*+ furnace: 927TA48080V17***Cold climate designationAHRI reference: 217913047 | 16.00 | 9.00 | 26400 | 2.12 | EPA 4535698 → |
CVAVA3721XMA*+ furnace: 927TA66100V21***Cold climate designationAHRI reference: 217912668 | 16.00 | 9.00 | 26200 | 2.12 | EPA 4535985 → |
CVAVA3817XMA*+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 217912683 | 16.00 | 9.00 | 26000 | 2.12 | EPA 4536000 → |
CVAVA3817XMA*+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 217912698 | 16.00 | 9.00 | 26000 | 2.12 | EPA 4536015 → |
CVAVA3817XMA*+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 217912833 | 16.00 | 9.00 | 26200 | 2.12 | EPA 4536028 → |
CVAMA4321XMA*+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 217909599 | 16.00 | 8.50 | 25200 | 2.04 | EPA 4536134 → |
CVAMA4321XMA*+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 217909614 | 16.00 | 8.50 | 24800 | 2.05 | EPA 4536150 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →