249VAN024**AA*
Preferred 19 SEER2 VS HP · source records, page 16
1,147 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 249VAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,147 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,147 / 1,147 |
| EER2 · BTU/Wh | 11.5–14 | 1,147 / 1,147 |
| HSPF2 · BTU/Wh | 8–10 | 1,147 / 1,147 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,147 / 1,147 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,147 / 1,147 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,147 / 1,147 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,147 / 1,147 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,147 / 1,147 |
| Equipment / loop type | HP - Split System | 1,147 / 1,147 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,147 / 1,147 |
| Compressor staging | Continuously variable | 1,147 / 1,147 |
| Connected capability | No | 1,147 / 1,147 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAMA3117XMA*+ furnace: 926TC48060V17***Cold climate designationAHRI reference: 217937441 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4555040 → |
CVAMA3117XMA*+ furnace: 926TC48080V17***Cold climate designationAHRI reference: 217937457 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4555052 → |
CVAVA3721XMA*+ furnace: 82*SB48070V17***Cold climate designationAHRI reference: 217942910 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4555075 → |
CVAVA3617XMA*+ furnace: 82*SB36045V14***Cold climate designationAHRI reference: 217941364 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4555085 → |
CVAVA3617XMA*+ furnace: 82*SB36070V14***Cold climate designationAHRI reference: 217941379 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4555100 → |
CVAMA3117XMA*+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217937364 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4555120 → |
CVAVA3721XMA*+ furnace: 82*SB48090V17***Cold climate designationAHRI reference: 217942925 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4555131 → |
CVAVA3721XMA*+ furnace: 82*SB60090V21***Cold climate designationAHRI reference: 217942940 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4555151 → |
CVAVA3721XMA*+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 217943030 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4555163 → |
CVAVA2517XMA*+ furnace: 927TA48080V17***Cold climate designationAHRI reference: 217940121 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4555237 → |
CVAMA3117XMA*+ furnace: 82*SB48090V17***Cold climate designationAHRI reference: 217937032 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4555284 → |
CVAMA3117XMA*+ furnace: 83*SB36040M17***Cold climate designationAHRI reference: 217937047 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4555299 → |
CVAMA3117XMA*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 217937062 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4555314 → |
CVAVA3617XMA*+ furnace: 82*TB36045V14***Cold climate designationAHRI reference: 217941514 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4555335 → |
CVAVA3617XMA*+ furnace: 82*TB36070V14***Cold climate designationAHRI reference: 217941529 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4555350 → |
CVAMA3117XMA*+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 217937077 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4555374 → |
CVAVA3617XMA*+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 217941349 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4555388 → |
CVAVA3617XMA*+ furnace: 82*TB48090V17***Cold climate designationAHRI reference: 217941545 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4555401 → |
CVAVA3617XMA*+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 217941546 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4555402 → |
CVAVA3017XMA*+ furnace: 926SB48080V17***Cold climate designationAHRI reference: 217940636 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4555455 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →