249VAN024**AA*
Preferred 19 SEER2 VS HP · source records, page 14
1,147 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 249VAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,147 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,147 / 1,147 |
| EER2 · BTU/Wh | 11.5–14 | 1,147 / 1,147 |
| HSPF2 · BTU/Wh | 8–10 | 1,147 / 1,147 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,147 / 1,147 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,147 / 1,147 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,147 / 1,147 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,147 / 1,147 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,147 / 1,147 |
| Equipment / loop type | HP - Split System | 1,147 / 1,147 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,147 / 1,147 |
| Compressor staging | Continuously variable | 1,147 / 1,147 |
| Connected capability | No | 1,147 / 1,147 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA3721XMA*+ furnace: 935SB48060M17***Cold climate designationAHRI reference: 217943376 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4554184 → |
CVAVA3721XMA*+ furnace: 935SB60080M21***Cold climate designationAHRI reference: 217943409 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4554199 → |
CVAVA3721XMA*+ furnace: 935SB60100M21***Cold climate designationAHRI reference: 217943440 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554214 → |
CVAVA2517XMA*+ furnace: 82*SB48090V17***Cold climate designationAHRI reference: 217939666 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554247 → |
CVAVA2517XMA*+ furnace: 83*SB36040M17***Cold climate designationAHRI reference: 217939681 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4554262 → |
CVAVA2517XMA*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 217939696 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554277 → |
CVAVA3017XMA*+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217940696 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4554299 → |
CVAVA3017XMA*+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 217940711 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554314 → |
CVAMA3217XMA*+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 217937697 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554325 → |
CVAVA3117XMA*+ furnace: 926TC48060V17***Cold climate designationAHRI reference: 217941274 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4554361 → |
CVAMA3017XMA*+ furnace: 82*SB48090V17***Cold climate designationAHRI reference: 217936472 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554391 → |
CVAMA3017XMA*+ furnace: 83*SB36040M17***Cold climate designationAHRI reference: 217936487 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4554408 → |
CVAMA3017XMA*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 217936502 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554425 → |
CVAVA3621XMA*+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 217942111 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4554436 → |
CVAVA3621XMA*+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 217942187 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554444 → |
CVAVA3621XMA*+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 217942126 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4554465 → |
CVAVA3017XMA*+ furnace: 935SB48060M17***Cold climate designationAHRI reference: 217940666 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4554516 → |
CVAVA3621XMA*+ furnace: 82*TB48070V17***Cold climate designationAHRI reference: 217942141 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554538 → |
CVAMA2517XMA*+ furnace: 927TA48080V17***Cold climate designationAHRI reference: 217936352 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4554580 → |
CVAVA3817XMA*+ furnace: 82*TB36045V14***Cold climate designationAHRI reference: 217944153 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4554605 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →