BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN048**AA*

2-STAGE 18 SEER HP · source records, page 11

417 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for 248TAN048**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 417 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18417 / 417
EER2 · BTU/Wh11.7–13.5417 / 417
HSPF2 · BTU/Wh7.8–8.5417 / 417
Cooling capacity · BTU/h45,500–50,500417 / 417
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500417 / 417
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600417 / 417
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600417 / 417
COP at 5°F / −15°C2.06–2.32417 / 417
Equipment / loop typeHP - Split System417 / 417
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)417 / 417
Compressor stagingTwo-stage417 / 417
Connected capabilityNo417 / 417

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6021XMA*+TDRAHRI reference: 21562865616.508.00240002.15EPA 3950622 →
CVAMA4921XMA*+TDRAHRI reference: 21562852316.508.00240002.15EPA 3950762 →
CVAMA6021XMA*+TDRAHRI reference: 21562854216.508.00240002.15EPA 3950783 →
CVAMA6124XMA*+TDRAHRI reference: 21562858016.508.10242002.16EPA 3950819 →
CAA**6024AM*+ furnace: 83*SB60080M21***AHRI reference: 21563185416.508.10256002.20EPA 3952567 →
CAA**6121AM*+ furnace: 88*TB60090C21***AHRI reference: 21563246816.508.10254002.22EPA 3952764 →
CAA**6121AM*+ furnace: 88*TB60110C21***AHRI reference: 21563248216.508.10258002.20EPA 3952780 →
CAA**6121AM*+ furnace: 987MC66100C21***AHRI reference: 21563260216.508.10260002.20EPA 3952958 →
CAA**6121AM*+ furnace: 82*SB60090V21***AHRI reference: 21563234316.508.10256002.22EPA 3953016 →
CAA**6121AM*+ furnace: 82*SB66110V21***AHRI reference: 21563235616.508.10254002.22EPA 3953027 →
CAA**6121AM*+ furnace: 83*SB48060M17***AHRI reference: 21563236916.508.10254002.22EPA 3953041 →
CAA**6121AM*+ furnace: 83*SB60080M21***AHRI reference: 21563238816.508.10252002.22EPA 3953063 →
CAA**6121AM*+ furnace: 83*SB60100M21***AHRI reference: 21563240716.508.10258002.22EPA 3953080 →
CAA**6121AM*+ furnace: 82*TB60090V21***AHRI reference: 21563251216.508.10256002.22EPA 3953096 →
CAA**6121AM*+ furnace: 935SB66100M21***AHRI reference: 21563269916.508.10256002.22EPA 3953214 →
CAA**6124AM*+ furnace: 83*SB60080M21***AHRI reference: 21563283016.508.10256002.20EPA 3953383 →
CVAMA6021XMA*+ furnace: 987TA60080C21***AHRI reference: 21572203116.508.00252002.10EPA 3981674 →
CVAMA6021XMA*+ furnace: 927TA60080V21***AHRI reference: 21572205916.508.00248002.12EPA 3981699 →
CVAMA6021XMA*+ furnace: 927TA60100V21***AHRI reference: 21572207516.508.00246002.14EPA 3981720 →
CVAVA4821XMA*+ furnace: 83*CB60080C21***AHRI reference: 21572210616.508.00240002.14EPA 3981747 →