BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN048**AA*

2-STAGE 18 SEER HP · source records, page 10

417 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for 248TAN048**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 417 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18417 / 417
EER2 · BTU/Wh11.7–13.5417 / 417
HSPF2 · BTU/Wh7.8–8.5417 / 417
Cooling capacity · BTU/h45,500–50,500417 / 417
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500417 / 417
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600417 / 417
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600417 / 417
COP at 5°F / −15°C2.06–2.32417 / 417
Equipment / loop typeHP - Split System417 / 417
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)417 / 417
Compressor stagingTwo-stage417 / 417
Connected capabilityNo417 / 417

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6021XMA*+ furnace: 926SB60100V21***AHRI reference: 21562489816.508.10248002.14EPA 3948931
CVAVA6021XMA*+ furnace: 935SB60080M21***AHRI reference: 21562491116.508.10250002.12EPA 3948944
CVAVA4924XMA*+ furnace: 986TD66120C24***AHRI reference: 21562465516.508.10252002.10EPA 3948969
CVAVA4924XMA*+ furnace: 926TC60080V21***AHRI reference: 21562466916.508.10254002.10EPA 3949014
CVAVA4924XMA*+ furnace: 926TC60100V21***AHRI reference: 21562468716.508.10254002.10EPA 3949037
CVAVA6021XMA*+ furnace: 926TC60080V21***AHRI reference: 21562496316.508.10248002.12EPA 3949102
CVAVA6021XMA*+ furnace: 926TC60100V21***AHRI reference: 21562498116.508.10246002.14EPA 3949122
CVAVA6021XMA*+ furnace: 88*TB60070C21***AHRI reference: 21562478316.508.10256002.06EPA 3949190
CVAVA6121XMA*+ furnace: 88*TB60070C21***AHRI reference: 21562509516.508.10256002.08EPA 3949306
CVAVA6124XMA*+ furnace: 935SB60080M21***AHRI reference: 21562561916.508.10252002.12EPA 3949393
CVAVA6124XMA*+ furnace: 88*TB60070C21***AHRI reference: 21562544016.508.10256002.10EPA 3949476
CVAVA6121XMA*+ furnace: 935SB60080M21***AHRI reference: 21562525316.508.10252002.10EPA 3949548
CVAVA6124XMA*+ furnace: 935CB60080C21***AHRI reference: 21562552416.508.10256002.08EPA 3949642
CVAVA6124XMA*+ furnace: 987MC66120C24***AHRI reference: 21562556616.508.10252002.12EPA 3949672
CVAVA6124XMA*+ furnace: 986TD60080C21***AHRI reference: 21562567116.508.10256002.10EPA 3949999
CVAVA6124XMA*+ furnace: 926TC66120V24***AHRI reference: 21562576416.508.10252002.12EPA 3950160
CVAVA6121XMA*+TDRAHRI reference: 21562869416.508.10242002.16EPA 3950468
CVAVA6124XMA*+TDRAHRI reference: 21562871316.508.10242002.16EPA 3950487
CAA**6121AM*+ furnace: 926TC66100V21***AHRI reference: 21562882716.508.10252002.24EPA 3950502
CVAVA4821XMA*+ furnace: 82*SB66110V21***AHRI reference: 21562884016.508.10242002.14EPA 3950518