BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN036**AA*

2-STAGE 18 SEER HP · source records, page 7

274 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for 248TAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17274 / 274
EER2 · BTU/Wh11.7–13274 / 274
HSPF2 · BTU/Wh7.8–8.5274 / 274
Cooling capacity · BTU/h33,800–38,000274 / 274
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000274 / 274
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200274 / 274
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600274 / 274
COP at 5°F / −15°C1.78–2.48274 / 274
Equipment / loop typeHP - Split System274 / 274
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)274 / 274
Compressor stagingTwo-stage274 / 274
Connected capabilityNo274 / 274

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**4321AM*+ furnace: 88*TB60110C21***AHRI reference: 21563795115.508.10193002.24EPA 3955765
CAA**4321AM*+ furnace: 82*TB48070V17***AHRI reference: 21563797215.508.10194002.24EPA 3955782
CAA**4821AM*+ furnace: 82*SB60090V21***AHRI reference: 21563878515.508.10192002.26EPA 3955802
CAA**4821AM*+ furnace: 82*SB66110V21***AHRI reference: 21563880415.508.10191002.24EPA 3955816
CAA**4821AM*+ furnace: 83*SB36040M17***AHRI reference: 21563882415.508.10192002.24EPA 3955828
CAA**4821AM*+ furnace: 83*SB48060M17***AHRI reference: 21563885215.508.10190002.28EPA 3955849
CAA**4321AM*+ furnace: 82*TB48090V17***AHRI reference: 21563799615.508.10193002.26EPA 3955860
CAA**4321AM*+ furnace: 82*TB60090V21***AHRI reference: 21563801115.508.10193002.24EPA 3955871
CAA**4321AM*+ furnace: 82*TB66110V21***AHRI reference: 21563803515.508.10192002.40EPA 3955888
CAA**4321AM*+ furnace: 935CB60080C21***AHRI reference: 21563808515.508.10193002.26EPA 3955918
CAA**4321AM*+ furnace: 935CB66100C21***AHRI reference: 21563810415.508.10193002.26EPA 3955934
CAA**4321AM*+ furnace: 987MC60080C21***AHRI reference: 21563819115.508.10193002.26EPA 3955960
CAA**4321AM*+ furnace: 987MC66100C21***AHRI reference: 21563821215.508.10193002.24EPA 3955974
CAA**4321AM*+ furnace: 935SB60100M21***AHRI reference: 21563836715.508.10194002.24EPA 3956001
CAA**4821AM*+ furnace: 83*SB60100M21***AHRI reference: 21563891015.508.10193002.22EPA 3956140
CAA**4821AM*+ furnace: 88*TB60090C21***AHRI reference: 21563902315.508.10190002.26EPA 3956201
CAA**4821AM*+ furnace: 88*TB60110C21***AHRI reference: 21563904315.508.10191002.26EPA 3956225
CAA**4821AM*+ furnace: 82*TB60090V21***AHRI reference: 21563910015.508.10192002.26EPA 3956254
CAA**4821AM*+ furnace: 82*TB66110V21***AHRI reference: 21563912415.508.10191002.26EPA 3956273
CAA**4821AM*+ furnace: 935CB66100C21***AHRI reference: 21563919815.508.10190002.26EPA 3956303

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →