BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN036**AA*

2-STAGE 18 SEER HP · source records, page 6

274 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for 248TAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17274 / 274
EER2 · BTU/Wh11.7–13274 / 274
HSPF2 · BTU/Wh7.8–8.5274 / 274
Cooling capacity · BTU/h33,800–38,000274 / 274
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000274 / 274
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200274 / 274
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600274 / 274
COP at 5°F / −15°C1.78–2.48274 / 274
Equipment / loop typeHP - Split System274 / 274
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)274 / 274
Compressor stagingTwo-stage274 / 274
Connected capabilityNo274 / 274

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3721AM*+ furnace: 986TD66100C21***AHRI reference: 21563623115.508.10193002.24EPA 3955089
CAA**3721AM*+ furnace: 926TC60080V21***AHRI reference: 21563631515.508.10193002.26EPA 3955101
CAA**3721AM*+ furnace: 926TC60100V21***AHRI reference: 21563634515.508.10193002.26EPA 3955120
CAA**4221AM*+ furnace: 83*SB60080M21***AHRI reference: 21563663915.508.10188002.24EPA 3955182
CAA**4221AM*+ furnace: 82*TB60090V21***AHRI reference: 21563686015.508.10189002.24EPA 3955276
CAA**4221AM*+ furnace: 926TC66100V21***AHRI reference: 21563755915.508.10188002.26EPA 3955414
CAA**4321AM*+ furnace: 82*SB48070V17***AHRI reference: 21563765615.508.10194002.24EPA 3955452
CAA**4321AM*+ furnace: 82*SB48090V17***AHRI reference: 21563767515.508.10193002.26EPA 3955469
CAA**4321AM*+ furnace: 82*SB60090V21***AHRI reference: 21563769415.508.10193002.24EPA 3955480
CAA**4321AM*+ furnace: 83*SB36040M17***AHRI reference: 21563773315.508.10193002.24EPA 3955509
CAA**4321AM*+ furnace: 83*SB60100M21***AHRI reference: 21563781715.508.10194002.24EPA 3955564
CAA**4321AM*+ furnace: 926TC60100V21***AHRI reference: 21563859115.508.10192002.26EPA 3955595
CAA**4321AM*+ furnace: 88*TB60070C21***AHRI reference: 21563789015.508.10194002.24EPA 3955616
CAA**4321AM*+ furnace: 986TD66100C21***AHRI reference: 21563848515.508.10193002.24EPA 3955624
CAA**4321AM*+ furnace: 926SB60080V21***AHRI reference: 21563827015.508.10193002.26EPA 3955657
CAA**4321AM*+ furnace: 926TC60080V21***AHRI reference: 21563856415.508.10193002.26EPA 3955673
CAA**4321AM*+ furnace: 926SB60100V21***AHRI reference: 21563829015.508.10194002.26EPA 3955690
CAA**4321AM*+ furnace: 935SB60080M21***AHRI reference: 21563834015.508.10193002.26EPA 3955722
CAA**4321AM*+ furnace: 88*TB48090C17***AHRI reference: 21563791115.508.10193002.26EPA 3955735
CAA**4321AM*+ furnace: 88*TB60090C21***AHRI reference: 21563793115.508.10193002.24EPA 3955751