BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN036**AA*

2-STAGE 18 SEER HP · source records, page 4

274 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for 248TAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17274 / 274
EER2 · BTU/Wh11.7–13274 / 274
HSPF2 · BTU/Wh7.8–8.5274 / 274
Cooling capacity · BTU/h33,800–38,000274 / 274
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000274 / 274
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200274 / 274
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600274 / 274
COP at 5°F / −15°C1.78–2.48274 / 274
Equipment / loop typeHP - Split System274 / 274
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)274 / 274
Compressor stagingTwo-stage274 / 274
Connected capabilityNo274 / 274

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA3817XMA*+ furnace: 82*TB48070V17***AHRI reference: 21562142715.507.80177001.80EPA 3946940 →
CVAVA4821XMA*+ furnace: 82*SB60090V21***AHRI reference: 21562246415.507.80177001.80EPA 3946956 →
CVAVA3817XMA*+ furnace: 987MC42080C17***AHRI reference: 21562148115.507.80179001.78EPA 3946982 →
CVAVA3817XMA*+ furnace: 926SB48080V17***AHRI reference: 21562150815.507.80179001.80EPA 3947010 →
CVAVA3817XMA*+ furnace: 935SB48060M17***AHRI reference: 21562152115.507.80178001.78EPA 3947018 →
CVAVA3817XMA*+ furnace: 986TD42080C17***AHRI reference: 21562154015.507.80178001.80EPA 3947040 →
CVAVA3817XMA*+ furnace: 926TC48080V17***AHRI reference: 21562157615.507.80179001.80EPA 3947072 →
CVAVA4821XMA*+ furnace: 83*CA60080C21***AHRI reference: 21562242415.507.80176001.78EPA 3947114 →
CVAVA4821XMA*+ furnace: 82*SB66110V21***AHRI reference: 21562247715.507.80177001.78EPA 3947129 →
CVAVA4821XMA*+ furnace: 83*SB48060M17***AHRI reference: 21562249015.507.80177001.78EPA 3947141 →
CVAVA4821XMA*+ furnace: 83*SB60080M21***AHRI reference: 21562250915.507.80175001.80EPA 3947162 →
CVAVA4821XMA*+ furnace: 88*TB60110C21***AHRI reference: 21562260315.507.80177001.80EPA 3947180 →
CVAVA4821XMA*+ furnace: 82*TB60090V21***AHRI reference: 21562264315.507.80177001.80EPA 3947197 →
CVAVA4821XMA*+ furnace: 935CB66100C21***AHRI reference: 21562267315.507.80178001.78EPA 3947214 →
CVAVA4821XMA*+ furnace: 986TD60080C21***AHRI reference: 21562279115.507.80178001.78EPA 3947249 →
CVAVA4821XMA*+ furnace: 926TC66100V21***AHRI reference: 21562288115.507.80176001.80EPA 3947302 →
CAA**3717AM*+ furnace: 83*CA36040C17***AHRI reference: 21563513015.508.10189002.28EPA 3954407 →
CAA**3721AM*+ furnace: 82*SB48090V17***AHRI reference: 21563565815.508.10193002.26EPA 3954509 →
CAA**3717AM*+ furnace: 82*SB48090V17***AHRI reference: 21563519715.508.10189002.28EPA 3954540 →
CAA**3717AM*+ furnace: 83*SB36040M17***AHRI reference: 21563521015.508.10188002.26EPA 3954557 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.