BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN036**AA*

2-STAGE 18 SEER HP · source records, page 3

274 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for 248TAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17274 / 274
EER2 · BTU/Wh11.7–13274 / 274
HSPF2 · BTU/Wh7.8–8.5274 / 274
Cooling capacity · BTU/h33,800–38,000274 / 274
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000274 / 274
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200274 / 274
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600274 / 274
COP at 5°F / −15°C1.78–2.48274 / 274
Equipment / loop typeHP - Split System274 / 274
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)274 / 274
Compressor stagingTwo-stage274 / 274
Connected capabilityNo274 / 274

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA4821XMA*+ furnace: 82*SB66110V21***AHRI reference: 21561950215.507.80177001.78EPA 3946288
CVAMA4821XMA*+ furnace: 83*SB48060M17***AHRI reference: 21561951515.507.80177001.78EPA 3946313
CVAMA4821XMA*+ furnace: 935CB66100C21***AHRI reference: 21561967015.507.80178001.78EPA 3946364
CVAMA4821XMA*+ furnace: 986TD60080C21***AHRI reference: 21561976915.507.80178001.78EPA 3946430
CVAMA4821XMA*+ furnace: 926TC60100V21***AHRI reference: 21561984115.507.80178001.78EPA 3946460
CVAVA3817XMA*+ furnace: 82*SB48070V17***AHRI reference: 21562129715.507.80177001.78EPA 3946489
CVAMA4821XMA*+ furnace: 926TC66100V21***AHRI reference: 21561985915.507.80176001.80EPA 3946516
CVAMA4921XMA*+ furnace: 82*SB48090V17***AHRI reference: 21561987215.507.80180001.78EPA 3946528
CVAMA4921XMA*+ furnace: 88*TB48090C17***AHRI reference: 21561991715.507.80180001.78EPA 3946575
CVAMA4921XMA*+ furnace: 88*TB60090C21***AHRI reference: 21561993115.507.80178001.82EPA 3946589
CVAMA4921XMA*+ furnace: 82*TB48090V17***AHRI reference: 21561996115.507.80180001.78EPA 3946617
CVAVA3721XMA*+ furnace: 82*SB60090V21***AHRI reference: 21562091615.507.80177001.80EPA 3946691
CVAVA3721XMA*+ furnace: 82*SB66110V21***AHRI reference: 21562092915.507.80177001.78EPA 3946704
CVAVA3721XMA*+ furnace: 986TD60080C21***AHRI reference: 21562115315.507.80178001.78EPA 3946719
CVAVA3721XMA*+ furnace: 926TC66100V21***AHRI reference: 21562124315.507.80176001.80EPA 3946768
CVAVA3817XMA*+ furnace: 83*CA36040C17***AHRI reference: 21562125615.507.80178001.80EPA 3946783
CVAVA3721XMA*+ furnace: 83*SB48060M17***AHRI reference: 21562094215.507.80177001.78EPA 3946789
CVAVA3721XMA*+ furnace: 82*TB60090V21***AHRI reference: 21562102415.507.80177001.80EPA 3946807
CVAVA3721XMA*+ furnace: 935CB66100C21***AHRI reference: 21562105415.507.80178001.78EPA 3946825
CVAVA3817XMA*+ furnace: 88*TB48070C17***AHRI reference: 21562138915.507.80177001.78EPA 3946910

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →