BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN036**AA*

2-STAGE 18 SEER HP · source records, page 11

274 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for 248TAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17274 / 274
EER2 · BTU/Wh11.7–13274 / 274
HSPF2 · BTU/Wh7.8–8.5274 / 274
Cooling capacity · BTU/h33,800–38,000274 / 274
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000274 / 274
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200274 / 274
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600274 / 274
COP at 5°F / −15°C1.78–2.48274 / 274
Equipment / loop typeHP - Split System274 / 274
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)274 / 274
Compressor stagingTwo-stage274 / 274
Connected capabilityNo274 / 274

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3721AM*+ furnace: 935SB48060M17***AHRI reference: 21563606915.208.10196002.24EPA 3955009 →
CAA**3721AM*+ furnace: 986TD42080C17***AHRI reference: 21563618515.208.10196002.24EPA 3955073 →
CAA**4221AM*+ furnace: 82*SB48090V17***AHRI reference: 21563650715.208.10188002.22EPA 3955147 →
CAA**4221AM*+ furnace: 83*SB48060M17***AHRI reference: 21563660615.208.10188002.24EPA 3955162 →
CAA**4221AM*+ furnace: 88*TB48090C17***AHRI reference: 21563675115.208.10189002.22EPA 3955199 →
CAA**4221AM*+ furnace: 82*SB60090V21***AHRI reference: 21563652715.208.10189002.24EPA 3955213 →
CAA**4221AM*+ furnace: 82*SB66110V21***AHRI reference: 21563654915.208.10188002.24EPA 3955228 →
CAA**4221AM*+ furnace: 88*TB60090C21***AHRI reference: 21563677615.208.10189002.24EPA 3955241 →
CAA**4221AM*+ furnace: 88*TB60110C21***AHRI reference: 21563679815.208.10188002.24EPA 3955252 →
CAA**4221AM*+ furnace: 82*TB48090V17***AHRI reference: 21563684315.208.10188002.22EPA 3955265 →
CAA**4221AM*+ furnace: 82*TB66110V21***AHRI reference: 21563688515.208.10188002.24EPA 3955293 →
CAA**4221AM*+ furnace: 935CB66100C21***AHRI reference: 21563697115.208.10189002.24EPA 3955310 →
CAA**4221AM*+ furnace: 987MC60080C21***AHRI reference: 21563707715.208.10188002.22EPA 3955326 →
CAA**4221AM*+ furnace: 987MC66100C21***AHRI reference: 21563710515.208.10188002.24EPA 3955339 →
CAA**4221AM*+ furnace: 926SB60100V21***AHRI reference: 21563719715.208.10190002.22EPA 3955353 →
CAA**4221AM*+ furnace: 935SB60100M21***AHRI reference: 21563728915.208.10188002.24EPA 3955365 →
CAA**4221AM*+ furnace: 935SB66100M21***AHRI reference: 21563732615.208.10188002.24EPA 3955384 →
CAA**4221AM*+ furnace: 986TD66100C21***AHRI reference: 21563741615.208.10188002.24EPA 3955399 →
CAA**4321AM*+ furnace: 83*CA36040C17***AHRI reference: 21563759615.208.10196002.24EPA 3955426 →
CAA**4321AM*+ furnace: 83*CA60080C21***AHRI reference: 21563763515.208.10195002.24EPA 3955442 →