BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN036**AA*

2-STAGE 18 SEER HP · source records, page 10

274 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for 248TAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17274 / 274
EER2 · BTU/Wh11.7–13274 / 274
HSPF2 · BTU/Wh7.8–8.5274 / 274
Cooling capacity · BTU/h33,800–38,000274 / 274
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000274 / 274
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200274 / 274
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600274 / 274
COP at 5°F / −15°C1.78–2.48274 / 274
Equipment / loop typeHP - Split System274 / 274
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)274 / 274
Compressor stagingTwo-stage274 / 274
Connected capabilityNo274 / 274

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3717AM*+ furnace: 926TC48060V17***AHRI reference: 21563552315.208.10190002.24EPA 3954365
CAA**3617AM*+ furnace: 83*SB48060M17***AHRI reference: 21563482715.207.80186002.26EPA 3954385
CAA**3717AM*+ furnace: 83*CA48060C17***AHRI reference: 21563514415.208.10192002.22EPA 3954419
CAA**3717AM*+ furnace: 82*SB36045V14***AHRI reference: 21563515815.208.10189002.26EPA 3954438
CAA**3717AM*+ furnace: 82*SB36070V14***AHRI reference: 21563517115.208.10189002.26EPA 3954444
CAA**3717AM*+ furnace: 926TC48080V17***AHRI reference: 21563554315.208.10189002.24EPA 3954452
CAA**3721AM*+ furnace: 83*CA36040C17***AHRI reference: 21563560315.208.10196002.22EPA 3954483
CAA**3721AM*+ furnace: 83*CA60080C21***AHRI reference: 21563563115.208.10195002.24EPA 3954490
CAA**3721AM*+ furnace: 82*SB48070V17***AHRI reference: 21563564515.208.10194002.26EPA 3954502
CAA**3717AM*+ furnace: 82*SB48070V17***AHRI reference: 21563518415.208.10189002.26EPA 3954527
CAA**3721AM*+ furnace: 88*TB48070C17***AHRI reference: 21563577915.208.10195002.24EPA 3954660
CAA**3721AM*+ furnace: 82*TB48070V17***AHRI reference: 21563584915.208.10194002.26EPA 3954727
CAA**3717AM*+ furnace: 88*TB36070C14***AHRI reference: 21563526215.208.10190002.26EPA 3954825
CAA**3717AM*+ furnace: 88*TB48070C17***AHRI reference: 21563527615.208.10190002.26EPA 3954837
CAA**3717AM*+ furnace: 88*TB48090C17***AHRI reference: 21563529015.208.10189002.26EPA 3954852
CAA**3717AM*+ furnace: 82*TB36045V14***AHRI reference: 21563530415.208.10189002.26EPA 3954869
CAA**3717AM*+ furnace: 82*TB36070V14***AHRI reference: 21563532215.208.10189002.26EPA 3954884
CAA**3717AM*+ furnace: 82*TB48070V17***AHRI reference: 21563533215.208.10189002.26EPA 3954894
CAA**3717AM*+ furnace: 82*TB48090V17***AHRI reference: 21563534815.208.10189002.28EPA 3954912
CAA**3717AM*+ furnace: 935CB48060C17***AHRI reference: 21563535815.208.10189002.26EPA 3954920

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.