BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

246SAN031**AA*

PREFERRED 16 SEER2 HP · source records, page 2

41 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity27,400–29,400BTU/h

Each efficiency range summarizes published EPA records for 246SAN031**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 41 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1641 / 41
EER2 · BTU/Wh11.7–1341 / 41
HSPF2 · BTU/Wh7.8–841 / 41
Cooling capacity · BTU/h27,400–29,40041 / 41
Heating capacity at 47°F / 8.3°C · BTU/h29,400–30,60041 / 41
Heating capacity at 17°F / −8.3°C · BTU/h17,500–18,20041 / 41
Heating capacity at 5°F / −15°C · BTU/h13,400–14,00041 / 41
COP at 5°F / −15°C2–2.0641 / 41
Equipment / loop typeHP - Split System41 / 41
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)41 / 41
Compressor stagingSingle stage41 / 41
Connected capabilityNo41 / 41

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FEVB0036**+NAVA53601CKAHRI reference: 21768321015.507.80134002.00EPA 4505967
F55AA*B30L*AHRI reference: 21768322115.507.80134002.00EPA 4505976
PF5MN*B30L*AHRI reference: 21768322015.507.80134002.00EPA 4505977
CAA**4321AM*+ furnace: 935SB66100M21***AHRI reference: 21768119715.508.00140002.06EPA 4506186
CAA**4321AM*+ furnace: 926TC66100V21***AHRI reference: 21768126515.508.00140002.06EPA 4506418
CAA**4321AM*+ furnace: 927TA66100V21***AHRI reference: 21768129015.508.00140002.06EPA 4506423
CAA**3721AM*+ furnace: 83*CB36040C17***AHRI reference: 21768050415.508.00139002.06EPA 4506491
CAA**3721AM*+ furnace: 83*CB60080C21***AHRI reference: 21768051415.508.00140002.06EPA 4506579
CAA**3721AM*+ furnace: 8(0,1)*SB60090M21***AHRI reference: 21768054915.508.00140002.06EPA 4506583
CAA**3721AM*+ furnace: 8(0,1)*SB60110M21***AHRI reference: 21768055415.508.00140002.06EPA 4506589
CAA**3721AM*+ furnace: 82*SB66110V21***AHRI reference: 21768057415.508.00140002.06EPA 4506594
CAA**3721AM*+ furnace: 83*SB48060M17***AHRI reference: 21768058415.508.00140002.06EPA 4506599
CAA**3721AM*+ furnace: 912SE60080M21***AHRI reference: 21768069915.508.00140002.06EPA 4506652
CAA**3721AM*+ furnace: 912SE60100M21***AHRI reference: 21768070415.508.00140002.06EPA 4506657
CAA**3721AM*+ furnace: 912SE66100M21***AHRI reference: 21768070915.508.00140002.06EPA 4506662
CAA**4321AM*+ furnace: 912SE60080M21***AHRI reference: 21768112215.508.00140002.06EPA 4506667
CAA**4321AM*+ furnace: 912SE60100M21***AHRI reference: 21768112715.508.00140002.06EPA 4506672
CAA**4321AM*+ furnace: 912SE66100M21***AHRI reference: 21768113215.508.00140002.06EPA 4506677
FM(C,U)5S36**AL*AHRI reference: 21845249115.508.00135002.00EPA 4624318
FM(C,U)5S30**AL*AHRI reference: 21845247215.508.00135002.00EPA 4624337