BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

246SAN031**AA*

PREFERRED 16 SEER2 HP

41 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity27,400–29,400BTU/h

Each efficiency range summarizes published EPA records for 246SAN031**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 41 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1641 / 41
EER2 · BTU/Wh11.7–1341 / 41
HSPF2 · BTU/Wh7.8–841 / 41
Cooling capacity · BTU/h27,400–29,40041 / 41
Heating capacity at 47°F / 8.3°C · BTU/h29,400–30,60041 / 41
Heating capacity at 17°F / −8.3°C · BTU/h17,500–18,20041 / 41
Heating capacity at 5°F / −15°C · BTU/h13,400–14,00041 / 41
COP at 5°F / −15°C2–2.0641 / 41
Equipment / loop typeHP - Split System41 / 41
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)41 / 41
Compressor stagingSingle stage41 / 41
Connected capabilityNo41 / 41

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
PF5MN*C42L*AHRI reference: 21768334516.008.00134002.05EPA 4505942
FJ5AN*C42L*AHRI reference: 21768334416.008.00134002.05EPA 4505943
F55AA*C42L*AHRI reference: 21768334616.008.00134002.05EPA 4505944
FMA5X30**AL*AHRI reference: 21768359516.008.00137002.00EPA 4506047
FM(C,U)5Z30**AL*AHRI reference: 21768346716.008.00134002.00EPA 4506684
FM(C,U)5Z36**AL*AHRI reference: 21768349916.008.00134002.00EPA 4506716
FMA5X36**AL*AHRI reference: 21768362716.008.00137002.00EPA 4506731
CAA**3721AM*+ furnace: 935SB66100M21***AHRI reference: 21768077415.508.00140002.06EPA 4505595
FJ5AN*B30L*AHRI reference: 21767993215.507.80134002.00EPA 4505601
CAA**3721AM*+ furnace: 83*SB60080M21***AHRI reference: 21768058915.508.00140002.04EPA 4505629
CAA**3721AM*+ furnace: 926TC66100V21***AHRI reference: 21768083715.508.00140002.06EPA 4505639
CAA**3721AM*+ furnace: 927TA66100V21***AHRI reference: 21768086215.508.00140002.06EPA 4505646
CAA**4321AM*+ furnace: 83*CB36040C17***AHRI reference: 21768092215.508.00139002.06EPA 4505673
CAA**4321AM*+ furnace: 83*CB60080C21***AHRI reference: 21768093215.508.00139002.04EPA 4505678
CAA**4321AM*+ furnace: 8(0,1)*SB60090M21***AHRI reference: 21768097215.508.00140002.06EPA 4505883
CAA**4321AM*+ furnace: 8(0,1)*SB60110M21***AHRI reference: 21768097715.508.00140002.04EPA 4505915
CAA**4321AM*+ furnace: 82*SB66110V21***AHRI reference: 21768099715.508.00140002.06EPA 4505919
CAA**4321AM*+ furnace: 83*SB48060M17***AHRI reference: 21768100715.508.00140002.06EPA 4505926
CAA**4321AM*+ furnace: 83*SB60080M21***AHRI reference: 21768101215.508.00140002.06EPA 4505931
FEVA0036**+NAVA53601CKAHRI reference: 21768320515.507.80134002.00EPA 4505963

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →