BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

246SAN018**AA*

PREFERRED 16 SEER2 HP · source records, page 2

50 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,400–18,900BTU/h

Each efficiency range summarizes published EPA records for 246SAN018**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 50 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.550 / 50
EER2 · BTU/Wh11.7–12.550 / 50
HSPF2 · BTU/Wh7.8–850 / 50
Cooling capacity · BTU/h17,400–18,90050 / 50
Heating capacity at 47°F / 8.3°C · BTU/h16,400–18,30050 / 50
Heating capacity at 17°F / −8.3°C · BTU/h10,500–11,00050 / 50
Heating capacity at 5°F / −15°C · BTU/h8,200–8,60050 / 50
COP at 5°F / −15°C1.88–2.150 / 50
Equipment / loop typeHP - Split System50 / 50
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)50 / 50
Compressor stagingSingle stage50 / 50
Connected capabilityNo50 / 50

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**2517AM*+ furnace: 83*SB48060M17***AHRI reference: 21412649315.207.8084002.06EPA 3399088 →
CAA**2517AM*+ furnace: 916SA48080M17***AHRI reference: 21412707815.207.8085002.04EPA 3399095 →
CAA**1917AM*+ furnace: 935SB48060M17***AHRI reference: 21412575915.207.8084002.04EPA 3399128 →
CAA**2517AM*+ furnace: 88*TB36070C14***AHRI reference: 21412655215.207.8084002.06EPA 3399174 →
CAA**2517AM*+ furnace: 935SB48060M17***AHRI reference: 21412718715.207.8085002.04EPA 3399199 →
CAA**1917AM*+ furnace: 82*SB48070V17***AHRI reference: 21412499615.207.8084002.04EPA 3399231 →
CAA**1917AM*+ furnace: 83*SA36040E17***AHRI reference: 21412502115.207.8083002.04EPA 3399256 →
CAA**1917AM*+ furnace: 986TD42080C17***AHRI reference: 21412581615.207.8084002.02EPA 3399304 →
CAA**2517AM*+ furnace: 986TD42080C17***AHRI reference: 21412724615.207.8084002.04EPA 3399331 →
CAA**2517AM*+ furnace: 926TC48060V17***AHRI reference: 21412733415.207.8084002.04EPA 3399361 →
CAA**1917AM*+ furnace: 83*SB36040M17***AHRI reference: 21412508115.207.8084002.04EPA 3399425 →
CAA**1917AM*+ furnace: 83*SB48060M17***AHRI reference: 21412511115.207.8084002.04EPA 3399456 →
CAA**1917AM*+ furnace: 88*TB36070C14***AHRI reference: 21412519515.207.8084002.04EPA 3399480 →
CAA**1917AM*+ furnace: 88*TB48090C17***AHRI reference: 21412524915.207.8084002.02EPA 3399509 →
CAA**2517AM*+ furnace: 912SE42060M17***AHRI reference: 21412698215.207.8084002.04EPA 3399709 →
CAA**2517AM*+ furnace: 88*TB48070C17***AHRI reference: 21412657915.207.8085002.04EPA 3399722 →
CAA**2517AM*+ furnace: 88*TB48090C17***AHRI reference: 21412660615.207.8085002.04EPA 3399749 →
CAA**2517AM*+ furnace: 82*SB36045V14***AHRI reference: 21412629715.207.8084002.04EPA 3399776 →
CAA**2517AM*+ furnace: 82*SB48070V17***AHRI reference: 21412634715.207.8084002.04EPA 3399802 →
CAA**1917AM*+ furnace: 82*SB36045V14***AHRI reference: 21412494615.207.8084002.04EPA 3399814 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →