BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

246SAN018**AA*

PREFERRED 16 SEER2 HP

50 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,400–18,900BTU/h

Each efficiency range summarizes published EPA records for 246SAN018**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 50 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.550 / 50
EER2 · BTU/Wh11.7–12.550 / 50
HSPF2 · BTU/Wh7.8–850 / 50
Cooling capacity · BTU/h17,400–18,90050 / 50
Heating capacity at 47°F / 8.3°C · BTU/h16,400–18,30050 / 50
Heating capacity at 17°F / −8.3°C · BTU/h10,500–11,00050 / 50
Heating capacity at 5°F / −15°C · BTU/h8,200–8,60050 / 50
COP at 5°F / −15°C1.88–2.150 / 50
Equipment / loop typeHP - Split System50 / 50
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)50 / 50
Compressor stagingSingle stage50 / 50
Connected capabilityNo50 / 50

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA3217XMA*+ furnace: 8(0,1)*SB36070M17***AHRI reference: 21419543615.507.8082001.94EPA 3406121
CVAMA3217XMA*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 21419546615.507.8082001.94EPA 3406151
FMA5X24**AL*AHRI reference: 21442391915.508.0082002.10EPA 3425242
CAA**2517AM*+ furnace: 82*TB36045V14***AHRI reference: 21412667315.207.8084002.04EPA 3398522
CAA**1917AM*+ furnace: 8(0,1)*SB36070M14***AHRI reference: 21412480115.207.8084002.04EPA 3398556
CAA**1917AM*+ furnace: 8(0,1)*SB36070M17***AHRI reference: 21412483115.207.8083002.04EPA 3398584
CAA**2517AM*+ furnace: 8(0,1)*SB36045M14***AHRI reference: 21412608415.207.8084002.04EPA 3398614
CAA**2517AM*+ furnace: 82*TB36070V14***AHRI reference: 21412670315.207.8084002.06EPA 3398668
CAA**2517AM*+ furnace: 82*TB48070V17***AHRI reference: 21412671515.207.8085002.04EPA 3398680
CAA**1917AM*+ furnace: 8(0,1)*SB36045M14***AHRI reference: 21412477115.207.8084002.02EPA 3398686
CAA**1917AM*+ furnace: 82*TB36070V14***AHRI reference: 21412531415.207.8084002.04EPA 3398692
CAA**2517AM*+ furnace: 8(0,1)*SB36070M14***AHRI reference: 21412614415.207.8084002.06EPA 3398700
CAA**2517AM*+ furnace: 8(0,1)*SB36070M17***AHRI reference: 21412617615.207.8084002.06EPA 3398733
CAA**2517AM*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 21412620615.207.8085002.06EPA 3398763
CAA**2517AM*+ furnace: 8(0,1)*SB42090M17***AHRI reference: 21412623815.207.8084002.04EPA 3398817
CAA**1917AM*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 21412485915.207.8084002.04EPA 3398858
CAA**1917AM*+ furnace: 8(0,1)*SB42090M17***AHRI reference: 21412488915.207.8084002.04EPA 3398894
CAA**2517AM*+ furnace: 912SE48080M17***AHRI reference: 21412701415.207.8084002.06EPA 3398941
CAA**2517AM*+ furnace: 83*SA36040E17***AHRI reference: 21412639715.207.8084002.06EPA 3398992
CAA**2517AM*+ furnace: 83*SB36040M17***AHRI reference: 21412646115.207.8084002.06EPA 3399071