PH8TAN560**AA*
2-STAGE 18 SEER HP
49 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for PH8TAN560**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 49 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17.5 | 49 / 49 |
| EER2 · BTU/Wh | 11.7–13 | 49 / 49 |
| HSPF2 · BTU/Wh | 8–8.5 | 49 / 49 |
| Cooling capacity · BTU/h | 54,000–58,000 | 49 / 49 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–61,500 | 49 / 49 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 36,200–38,500 | 49 / 49 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,600–31,800 | 49 / 49 |
| COP at 5°F / −15°C | 2.12–2.34 | 49 / 49 |
| Equipment / loop type | HP - Split System | 49 / 49 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 49 / 49 |
| Compressor staging | Two-stage | 49 / 49 |
| Connected capability | No | 49 / 49 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
PF5TNBD60L*AHRI reference: 215560743 | 17.50 | 8.10 | 30200 | 2.30 | EPA 3982828 → |
QFVA5D6021X*AHRI reference: 218695461 | 17.50 | 8.10 | 31400 | 2.34 | EPA 4683366 → |
CAA**6024AM*+ furnace: PG80MSUA60080C**AHRI reference: 215629091 | 16.50 | 8.00 | 29600 | 2.30 | EPA 3951006 → |
CAA**6124AM*+ furnace: PG80MSUA60080C**AHRI reference: 215630051 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951416 → |
CAA**6124AM*+ furnace: PG80MSUA60100C**AHRI reference: 215630070 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951433 → |
CAA**6121AM*+ furnace: PG80MSUA60080C**AHRI reference: 215629612 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951567 → |
CAA**6124AM*+ furnace: PG80VTLB66110C**AHRI reference: 215630161 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951668 → |
CAA**6124AM*+ furnace: PG80VTLB66135D**AHRI reference: 215630179 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951684 → |
CAA**6121AM*+ furnace: PG80VTLB66110C**AHRI reference: 215629722 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951791 → |
CVAMA6124XMA*+ furnace: PG80VTLB60090C**AHRI reference: 215626636 | 16.00 | 8.50 | 31800 | 2.32 | EPA 3949853 → |
CVAMA6124XMA*+ furnace: PG80VTLB66135D**AHRI reference: 215626670 | 16.00 | 8.50 | 31400 | 2.34 | EPA 3949866 → |
CVAVA6021XMA*+ furnace: PG80MSUA48060B**AHRI reference: 215627016 | 16.00 | 8.10 | 30600 | 2.22 | EPA 3949915 → |
CVAVA6021XMA*+ furnace: PG80MSUA60080C**AHRI reference: 215627035 | 16.00 | 8.10 | 30400 | 2.22 | EPA 3949934 → |
CVAVA6021XMA*+ furnace: PG80MSUA60100C**AHRI reference: 215627054 | 16.00 | 8.10 | 30400 | 2.22 | EPA 3949953 → |
CVAVA6021XMA*+ furnace: PG80VTLB60090C**AHRI reference: 215627115 | 16.00 | 8.10 | 30400 | 2.20 | EPA 3950071 → |
CVAVA6021XMA*+ furnace: PG80VTLB66110C**AHRI reference: 215627131 | 16.00 | 8.10 | 30400 | 2.22 | EPA 3950090 → |
CVAMA6021XMA*+ furnace: PG80MSUA48060B**AHRI reference: 215625825 | 16.00 | 8.10 | 30000 | 2.22 | EPA 3950189 → |
CVAMA6021XMA*+ furnace: PG80MSUA60080C**AHRI reference: 215625844 | 16.00 | 8.10 | 29800 | 2.24 | EPA 3950210 → |
CVAMA6021XMA*+ furnace: PG80MSUA60100C**AHRI reference: 215625863 | 16.00 | 8.10 | 30400 | 2.24 | EPA 3950226 → |
CVAMA6021XMA*+ furnace: PG80VTLB66110C**AHRI reference: 215625954 | 16.00 | 8.10 | 30000 | 2.24 | EPA 3950276 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.