BROCK / AIR-SOURCE HEAT PUMP

PH5SAN524**AA*

15 SEER2 HP

116 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for PH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 116 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5116 / 116
EER2 · BTU/Wh11.7–13116 / 116
HSPF2 · BTU/Wh7.8–8.5116 / 116
Cooling capacity · BTU/h22,200–24,400116 / 116
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000116 / 116
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200116 / 116
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900116 / 116
COP at 5°F / −15°C1.98–2.26116 / 116
Equipment / loop typeHP - Split System116 / 116
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)116 / 116
Compressor stagingSingle stage116 / 116
Connected capabilityNo116 / 116

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FMA5X30**AL*AHRI reference: 21442407516.508.50116002.26EPA 3425083
CVAVA3117XMA*+ furnace: PG80VTLB48090B**AHRI reference: 21420521016.007.80113001.98EPA 3408937
CVAMA3217XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21421274016.007.80113002.00EPA 3408991
CVAVA3817XMA*+ furnace: PG80VTLB48070B**AHRI reference: 21421436016.007.80114002.00EPA 3409014
CVAVA3817XMA*+ furnace: PG80VTLB48090B**AHRI reference: 21421438816.007.80114002.00EPA 3409043
CVAVA3721XMA*+ furnace: PG80MS(A,L)A48090C**AHRI reference: 21421339716.007.80112001.98EPA 3409071
CVAVA3817XMA*+ furnace: PG92MSAA42060B**AHRI reference: 21421448716.007.80114002.00EPA 3409527
CAA**3721AM*+ furnace: PG95MSUA60100C**AHRI reference: 21421197216.007.80115002.14EPA 3409822
CVAMA3217XMA*+ furnace: PG80VTLB48090B**AHRI reference: 21421289616.007.80114001.98EPA 3409898
CVAMA3217XMA*+ furnace: PG92MSAA48080B**AHRI reference: 21421300016.007.80112001.98EPA 3410188
CAA**2517AM*+ furnace: PG80MSUA36040B**AHRI reference: 21421053216.007.80113002.12EPA 3410503
CAA**2517AM*+ furnace: PG80MSUA48060B**AHRI reference: 21421056416.007.80112002.12EPA 3410536
CVAVA3817XMA*+ furnace: PG80MS(A,L)A36070B**AHRI reference: 21421397716.007.80114002.00EPA 3410638
CAA**3721AM*+ furnace: PG80VTLB66110C**AHRI reference: 21421149116.007.80115002.14EPA 3410743
CVAVA3817XMA*+ furnace: PG80MS(A,L)A48070B**AHRI reference: 21421400716.007.80114002.00EPA 3410765
CVAVA3817XMA*+ furnace: PG80MS(A,L)A42090B**AHRI reference: 21421403916.007.80112002.00EPA 3410800
CVAMA3117XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21421235216.007.80112001.98EPA 3410804
CVAVA3817XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21421423516.007.80112002.02EPA 3411135
CVAMA3217XMA*+ furnace: PG80MS(A,L)A42090B**AHRI reference: 21421254416.007.80112001.98EPA 3411158
CVAVA3117XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21421327616.007.80112002.00EPA 3411205