BROCK / AIR-SOURCE HEAT PUMP

PH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 3

150 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity46,000–50,500BTU/h

Each efficiency range summarizes published EPA records for PH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 150 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18150 / 150
EER2 · BTU/Wh11.7–13.5150 / 150
HSPF2 · BTU/Wh7.8–8.5150 / 150
Cooling capacity · BTU/h46,000–50,500150 / 150
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500150 / 150
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,400150 / 150
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600150 / 150
COP at 5°F / −15°C2.1–2.32150 / 150
Equipment / loop typeHP - Split System150 / 150
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)150 / 150
Compressor stagingTwo-stage150 / 150
Connected capabilityNo150 / 150

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
PF5TNXC48L*AHRI reference: 21562892117.008.10246002.28EPA 3950856
CVAVA6121XMA*+ furnace: PG97VTAA60080C**AHRI reference: 21572236917.008.00250002.10EPA 3982575
CVAVA6121XMA*+ furnace: PG97VTAA60100C**AHRI reference: 21572238517.008.00250002.12EPA 3982595
CVAVA6124XMA*+ furnace: PG97VTAA60080C**AHRI reference: 21572248617.008.00256002.10EPA 3982696
CVAVA6124XMA*+ furnace: PG97VTAA60100C**AHRI reference: 21572250217.008.00252002.12EPA 3982710
CVAMA4821XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21562293816.508.10246002.12EPA 3947341
CVAMA4821XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21562297616.508.10246002.12EPA 3947380
CVAMA4821XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562303716.508.10244002.12EPA 3947440
CVAMA4821XMA*+ furnace: PG80VTLB66110C**AHRI reference: 21562305316.508.10244002.14EPA 3947457
CVAMA4821XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21562315916.508.10244002.12EPA 3947503
CVAMA4921XMA*+ furnace: PG95MSUA60080C**AHRI reference: 21562352416.508.10250002.12EPA 3947834
CVAVA4821XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562419116.508.10244002.12EPA 3947905
CVAVA4821XMA*+ furnace: PG80VTLB66110C**AHRI reference: 21562420716.508.10242002.14EPA 3947920
CVAMA4921XMA*+ furnace: PG96VTAB60080C**AHRI reference: 21562360416.508.10250002.12EPA 3947987
CVAMA4921XMA*+ furnace: PG96VTAB60100C**AHRI reference: 21562362216.508.10250002.10EPA 3948005
CVAMA6021XMA*+ furnace: PG96VTAB60080C**AHRI reference: 21562400216.508.10248002.12EPA 3948010
CVAMA6021XMA*+ furnace: PG96VTAB60100C**AHRI reference: 21562402016.508.10246002.14EPA 3948032
CVAVA4821XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21562407816.508.10242002.14EPA 3948072
CVAVA4821XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21562411616.508.10246002.12EPA 3948109
CVAVA4821XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21562432116.508.10244002.12EPA 3948416