PH8TAN548**AA*
2-STAGE 18 SEER HP
150 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for PH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 150 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 150 / 150 |
| EER2 · BTU/Wh | 11.7–13.5 | 150 / 150 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 150 / 150 |
| Cooling capacity · BTU/h | 46,000–50,500 | 150 / 150 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 150 / 150 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,400 | 150 / 150 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 150 / 150 |
| COP at 5°F / −15°C | 2.1–2.32 | 150 / 150 |
| Equipment / loop type | HP - Split System | 150 / 150 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 150 / 150 |
| Compressor staging | Two-stage | 150 / 150 |
| Connected capability | No | 150 / 150 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
PF5TNBD60L*AHRI reference: 215560717 | 18.00 | 8.10 | 24600 | 2.32 | EPA 3982813 → |
QFVA5D6021X*AHRI reference: 218695444 | 18.00 | 8.50 | 25800 | 2.32 | EPA 4683383 → |
CVAMA4921XMA*+ furnace: PG80MSUA60080C**AHRI reference: 215623314 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3947637 → |
CVAMA6021XMA*+ furnace: PG80MSUA60080C**AHRI reference: 215623712 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3948274 → |
CVAVA4924XMA*+ furnace: PG80MSUA60080C**AHRI reference: 215624470 | 17.50 | 8.10 | 24600 | 2.14 | EPA 3948709 → |
CVAVA6121XMA*+ furnace: PG80MSUA48060B**AHRI reference: 215625042 | 17.50 | 8.10 | 25000 | 2.12 | EPA 3949255 → |
CVAVA6121XMA*+ furnace: PG80MSUA60080C**AHRI reference: 215625061 | 17.50 | 8.50 | 24400 | 2.30 | EPA 3949273 → |
CVAVA6121XMA*+ furnace: PG80MSUA60100C**AHRI reference: 215625080 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3949292 → |
CVAVA6121XMA*+ furnace: PG80VTLB66110C**AHRI reference: 215625157 | 17.50 | 8.10 | 24600 | 2.14 | EPA 3949454 → |
CVAVA6124XMA*+ furnace: PG80VTLB66135D**AHRI reference: 215625520 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3949638 → |
CVAVA6124XMA*+ furnace: PG80VTLB66110C**AHRI reference: 215625502 | 17.50 | 8.50 | 24800 | 2.28 | EPA 3949837 → |
QFVA5D4821X*AHRI reference: 218695427 | 17.50 | 8.10 | 25400 | 2.18 | EPA 4683400 → |
CVAMA4821XMA*+ furnace: PG80MSUA60080C**AHRI reference: 215622957 | 17.00 | 8.10 | 24000 | 2.14 | EPA 3947362 → |
CVAMA4921XMA*+ furnace: PG80MSUA48060B**AHRI reference: 215623295 | 17.00 | 8.10 | 25000 | 2.12 | EPA 3947619 → |
CVAMA4921XMA*+ furnace: PG80MSUA60100C**AHRI reference: 215623333 | 17.00 | 8.10 | 24800 | 2.10 | EPA 3947655 → |
CVAMA4921XMA*+ furnace: PG80VTLB60090C**AHRI reference: 215623394 | 17.00 | 8.10 | 25000 | 2.10 | EPA 3947717 → |
CVAMA4921XMA*+ furnace: PG80VTLB66110C**AHRI reference: 215623410 | 17.00 | 8.10 | 24800 | 2.12 | EPA 3947735 → |
CVAMA4921XMA*+ furnace: PG95MSUA60100C**AHRI reference: 215623543 | 17.00 | 8.10 | 25200 | 2.10 | EPA 3947853 → |
CVAVA4821XMA*+ furnace: PG80MSUA60080C**AHRI reference: 215624097 | 17.00 | 8.10 | 24000 | 2.14 | EPA 3948090 → |
CVAMA6021XMA*+ furnace: PG80MSUA48060B**AHRI reference: 215623693 | 17.00 | 8.10 | 25000 | 2.10 | EPA 3948183 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →