BROCK / AIR-SOURCE HEAT PUMP

PH8TAN536**AA*

2-STAGE 18 SEER HP · source records, page 2

105 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 105 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17105 / 105
EER2 · BTU/Wh11.7–13105 / 105
HSPF2 · BTU/Wh7.8–8.5105 / 105
Cooling capacity · BTU/h33,800–38,000105 / 105
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000105 / 105
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200105 / 105
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600105 / 105
COP at 5°F / −15°C1.78–2.48105 / 105
Equipment / loop typeHP - Split System105 / 105
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)105 / 105
Compressor stagingTwo-stage105 / 105
Connected capabilityNo105 / 105

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA3721XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562102815.507.80177001.80EPA 3946810
CVAVA3817XMA*+ furnace: PG80VTLB48070B**AHRI reference: 21562143115.507.80177001.80EPA 3946945
CVAVA3817XMA*+ furnace: PG95MSUA48060B**AHRI reference: 21562152515.507.80178001.78EPA 3947021
CVAVA3817XMA*+ furnace: PG96VTAB48080B**AHRI reference: 21562158015.507.80179001.80EPA 3947081
CVAVA4821XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21562249415.507.80177001.78EPA 3947143
CVAVA4821XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21562251315.507.80175001.80EPA 3947165
CVAVA4821XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562264715.507.80177001.80EPA 3947202
CAA**3717AM*+ furnace: PG80MSUA36040B**AHRI reference: 21563521415.508.10188002.26EPA 3954560
CAA**3721AM*+ furnace: PG80MSUA36040B**AHRI reference: 21563570115.508.10193002.26EPA 3954597
CAA**3721AM*+ furnace: PG80MSUA60080C**AHRI reference: 21563573515.508.10191002.42EPA 3954629
CAA**3721AM*+ furnace: PG80MSUA60100C**AHRI reference: 21563575215.508.10194002.26EPA 3954654
CAA**3721AM*+ furnace: PG80VTLB48090B**AHRI reference: 21563586915.508.10193002.26EPA 3954758
CAA**3721AM*+ furnace: PG80VTLB60090C**AHRI reference: 21563587715.508.10193002.26EPA 3954763
CAA**3721AM*+ furnace: PG80VTLB66110C**AHRI reference: 21563589315.508.10195002.24EPA 3954774
CAA**3717AM*+ furnace: PG80MSUA48060B**AHRI reference: 21563523315.508.10188002.28EPA 3954805
CAA**3721AM*+ furnace: PG95MSUA60080C**AHRI reference: 21563609515.508.10193002.26EPA 3955029
CAA**3721AM*+ furnace: PG95MSUA60100C**AHRI reference: 21563612015.508.10194002.24EPA 3955046
CAA**3721AM*+ furnace: PG96VTAB60080C**AHRI reference: 21563632115.508.10193002.26EPA 3955107
CAA**3721AM*+ furnace: PG96VTAB60100C**AHRI reference: 21563635115.508.10193002.26EPA 3955121
CAA**4221AM*+ furnace: PG80MSUA60080C**AHRI reference: 21563664715.508.10188002.24EPA 3955185

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.