BROCK / AIR-SOURCE HEAT PUMP

PH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 9

204 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 204 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5204 / 204
EER2 · BTU/Wh11.5–14204 / 204
HSPF2 · BTU/Wh7.8–8.5204 / 204
Cooling capacity · BTU/h22,200–25,000204 / 204
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,200204 / 204
Heating capacity at 17°F / −8.3°C · BTU/h14,100–14,900204 / 204
Heating capacity at 5°F / −15°C · BTU/h10,700–11,400204 / 204
COP at 5°F / −15°C1.9–2.24204 / 204
Equipment / loop typeHP - Split System204 / 204
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)204 / 204
Compressor stagingTwo-stage204 / 204
Connected capabilityNo204 / 204

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*2412AM*+ furnace: PG80VTLB36045A**AHRI reference: 21564925916.007.80110001.94EPA 3962085
CSAH*2412AM*+ furnace: PG80VTLB48070B**AHRI reference: 21564930216.007.80111001.92EPA 3962101
CSAH*2412AM*+ furnace: PG80VTLB66135D**AHRI reference: 21564938716.008.00111002.05EPA 3962118
CSAH*2412AM*+ furnace: PG96VTAB36060A**AHRI reference: 21565004616.008.00111002.05EPA 3962264
CSAH*2412AM*+ furnace: PG96VTAB48060B**AHRI reference: 21565007216.008.00111002.05EPA 3962287
CSAH*2412AM*+ furnace: PG96VTAB48080B**AHRI reference: 21565010116.007.80110001.94EPA 3962301
CSAH*2412AM*+ furnace: PG96VTAB60100C**AHRI reference: 21565015316.007.80111001.94EPA 3962329
CSAH*2412AM*+ furnace: PG80MSUA60100C**AHRI reference: 21564906716.007.80111002.00EPA 3962561
CSAH*2412AM*+ furnace: PG96VTAB66120D**AHRI reference: 21565020216.008.00111002.05EPA 3962898
CSAH*3012AM*+ furnace: PG80VTLB66135D**AHRI reference: 21565084316.008.00110002.06EPA 3962976
CSAH*3012AM*+ furnace: PG80MSUA60100C**AHRI reference: 21565052116.008.00112002.10EPA 3963228
CSAH*3012AM*+ furnace: PG96VTAB36040B**AHRI reference: 21565148616.008.00113002.05EPA 3963782
CSAH*3012AM*+ furnace: PG96VTAB36060A**AHRI reference: 21565150916.008.00112002.05EPA 3963807
CSAH*3012AM*+ furnace: PG96VTAB48060B**AHRI reference: 21565153616.007.80111002.06EPA 3964203
CSAH*3012AM*+ furnace: PG96VTAB48080B**AHRI reference: 21565156516.008.00111002.10EPA 3964223
CSAH*3612AM*+ furnace: PG96VTAB36040B**AHRI reference: 21565296216.008.00112002.05EPA 3965126
CSAH*3012AM*+ furnace: PG97VTAA48080B**AHRI reference: 21572110216.008.00111002.10EPA 3981057
CSAH*3012AM*+ furnace: PG97VTAA66120D**AHRI reference: 21572116716.007.80111002.06EPA 3981982
CSAH*3612AM*+ furnace: PG97VTAA60100C**AHRI reference: 21572123916.007.80110002.08EPA 3982055
CSAH*3612AM*+ furnace: PG96VTAB36060A**AHRI reference: 21565298516.008.00111002.05EPA 3996901