PH5SAN536**AA*
15 SEER2 HP
20 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for PH5SAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 20 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 20 / 20 |
| EER2 · BTU/Wh | 12–13 | 20 / 20 |
| HSPF2 · BTU/Wh | 7.8–8 | 20 / 20 |
| Cooling capacity · BTU/h | 33,800–36,800 | 20 / 20 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–36,400 | 20 / 20 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,800 | 20 / 20 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,100–18,100 | 20 / 20 |
| COP at 5°F / −15°C | 2–2.22 | 20 / 20 |
| Equipment / loop type | HP - Split System | 20 / 20 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 20 / 20 |
| Compressor staging | Single stage | 20 / 20 |
| Connected capability | No | 20 / 20 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FEVA0048**+NAVA54801CKAHRI reference: 217051639 | 16.00 | 8.00 | 17400 | 2.18 | EPA 4001108 → |
PF5TNXC48L*AHRI reference: 214179940 | 15.50 | 7.80 | 16700 | 2.18 | EPA 3404464 → |
PF5MN*C48L*AHRI reference: 214180182 | 15.50 | 7.80 | 17400 | 2.18 | EPA 3404799 → |
FEVB0048**+NAVA54801CKAHRI reference: 214277602 | 15.50 | 7.80 | 17400 | 2.22 | EPA 3415689 → |
FMA5X36**AL*AHRI reference: 214424291 | 15.50 | 7.80 | 17000 | 2.00 | EPA 3425180 → |
CAA**4321AM*+ furnace: PG80MS(A,L)A60110C**AHRI reference: 214139978 | 15.20 | 7.80 | 18000 | 2.20 | EPA 3400442 → |
CAA**4821AM*+ furnace: PG80VTLB60090C**AHRI reference: 214141947 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400613 → |
CAA**4821AM*+ furnace: PG80MS(A,L)A60090C**AHRI reference: 214141342 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400768 → |
CAA**4321AM*+ furnace: PG92MSAA60100C**AHRI reference: 214140515 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3400790 → |
CAA**4821AM*+ furnace: PG80MS(A,L)A60110C**AHRI reference: 214141372 | 15.20 | 7.80 | 17600 | 2.20 | EPA 3400841 → |
CAA**4821AM*+ furnace: PG92MSAA60100C**AHRI reference: 214142261 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3400873 → |
CVAMA4421XMA*+ furnace: PG80ESUA36040B**AHRI reference: 214143050 | 15.20 | 7.80 | 18100 | 2.14 | EPA 3401014 → |
CAA**3721AM*+ furnace: PG80MS(A,L)A60090C**AHRI reference: 214138232 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3401145 → |
CAA**4821AM*+ furnace: PG80MSUA48060B**AHRI reference: 214141634 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3401220 → |
CAA**4821AM*+ furnace: PG80MSUA60080C**AHRI reference: 214141666 | 15.20 | 7.80 | 17300 | 2.20 | EPA 3401263 → |
CAA**4321AM*+ furnace: PG80MS(A,L)A60090C**AHRI reference: 214139948 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3401310 → |
CVAVA4224XMA*+ furnace: PG80MSUA60100C**AHRI reference: 214144595 | 15.20 | 7.80 | 18100 | 2.14 | EPA 3401866 → |
PF5MN*C42L*AHRI reference: 214179898 | 15.20 | 7.80 | 16100 | 2.02 | EPA 3404668 → |
FM(C,U)5Z36**AL*AHRI reference: 215829103 | 15.20 | 7.80 | 17200 | 2.08 | EPA 3713516 → |
FM(C,U)5S36**AL*AHRI reference: 218452408 | 15.20 | 8.00 | 17300 | 2.00 | EPA 4624401 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →