PH5SAN531**AA*
15 SEER2 HP
23 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for PH5SAN531**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 23 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 23 / 23 |
| EER2 · BTU/Wh | 12–13 | 23 / 23 |
| HSPF2 · BTU/Wh | 7.8–8 | 23 / 23 |
| Cooling capacity · BTU/h | 27,400–29,400 | 23 / 23 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,400–30,600 | 23 / 23 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,500–18,100 | 23 / 23 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,400–14,000 | 23 / 23 |
| COP at 5°F / −15°C | 2–2.06 | 23 / 23 |
| Equipment / loop type | HP - Split System | 23 / 23 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 23 / 23 |
| Compressor staging | Single stage | 23 / 23 |
| Connected capability | No | 23 / 23 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
PF5MN*C42L*AHRI reference: 217683355 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4505953 → |
FMA5X30**AL*AHRI reference: 217683599 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4506051 → |
FM(C,U)5Z36**AL*AHRI reference: 217683503 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4506114 → |
FM(C,U)5Z30**AL*AHRI reference: 217683471 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4506688 → |
FMA5X36**AL*AHRI reference: 217683631 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4506736 → |
PF5MN*B30L*AHRI reference: 217683227 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4506026 → |
CAA**3721AM*+ furnace: PG92MSAA60080C**AHRI reference: 217690824 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506817 → |
CAA**3721AM*+ furnace: PG92MSAA60100C**AHRI reference: 217690847 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506840 → |
CAA**3721AM*+ furnace: PG80MS(A,L)A60090C**AHRI reference: 217690162 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506968 → |
CAA**3721AM*+ furnace: PG80MS(A,L)A60110C**AHRI reference: 217690187 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506993 → |
CAA**4321AM*+ furnace: PG92MSAA60080C**AHRI reference: 217692720 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507048 → |
CAA**4321AM*+ furnace: PG92MSAA60100C**AHRI reference: 217692743 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507070 → |
CAA**3721AM*+ furnace: PG80MSUA60080C**AHRI reference: 217690342 | 15.50 | 8.00 | 14000 | 2.04 | EPA 4507143 → |
CAA**4321AM*+ furnace: PG80MS(A,L)A60110C**AHRI reference: 217692065 | 15.50 | 8.00 | 14000 | 2.04 | EPA 4507217 → |
CAA**4321AM*+ furnace: PG80MS(A,L)A60090C**AHRI reference: 217692040 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507225 → |
CAA**3721AM*+ furnace: PG80MSUA48060B**AHRI reference: 217690317 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507250 → |
CAA**4321AM*+ furnace: PG80MSUA48060B**AHRI reference: 217692199 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507284 → |
CAA**4321AM*+ furnace: PG80MSUA60080C**AHRI reference: 217692226 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507316 → |
FEVA0036**+NAVA53601CKAHRI reference: 217702160 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4508697 → |
FEVB0036**+NAVA53601CKAHRI reference: 217702187 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4508848 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →