Breeze33 / AIR-SOURCE HEAT PUMP

HSZ18H424ZMO

HS series · HS-series

6 published source records · source checked Sep 21, 2026

SEER2 range17.6–20.5BTU/Wh
HSPF2 range8.9–11.2BTU/Wh
Cooling capacity16,000–18,000BTU/h

Each efficiency range summarizes published EPA records for HSZ18H424ZMO. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 6 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17.6–20.56 / 6
EER2 · BTU/Wh11–12.56 / 6
HSPF2 · BTU/Wh8.9–11.26 / 6
Cooling capacity · BTU/h16,000–18,0006 / 6
Heating capacity at 47°F / 8.3°C · BTU/h17,000–20,0006 / 6
Heating capacity at 17°F / −8.3°C · BTU/h12,000–15,6006 / 6
Heating capacity at 5°F / −15°C · BTU/h16,000–17,7006 / 6
COP at 5°F / −15°C1.75–26 / 6
Equipment / loop typeHP - Mini or Multi Split · HP - Split System6 / 6
Refrigerant / source-reported GWPR-410A (GWP:2088)6 / 6
Compressor stagingContinuously variable6 / 6
Connected capabilityNo6 / 6

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FC18H424ZMICold climate designationAHRI reference: 21127759220.509.80168001.86EPA 2469653
C18H424ZMICold climate designationAHRI reference: 21127759120.208.90167001.76EPA 2470172
CA18H424ZMICold climate designationAHRI reference: 21127758820.009.50160001.75EPA 2469652
SCA18H424ZMICold climate designationAHRI reference: 21127758919.8011.20167001.93EPA 2470099
D18H424ZMICold climate designationAHRI reference: 21127759018.009.50177001.85EPA 2470575
AH18H424ZMICold climate designationAHRI reference: 21127759717.609.60170002.00EPA 2478220

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.