Breeze33 / AIR-SOURCE HEAT PUMP

7HP19V60P-**A

7HP19V Series · source records, page 2

68 published source records · source checked Sep 21, 2026

SEER2 range16.5–18.2BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 7HP19V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 68 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.5–18.268 / 68
EER2 · BTU/Wh11–11.768 / 68
HSPF2 · BTU/Wh7.8–968 / 68
Cooling capacity · BTU/h46,000–48,00068 / 68
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,00068 / 68
Heating capacity at 17°F / −8.3°C · BTU/h27,600–32,60068 / 68
Heating capacity at 5°F / −15°C · BTU/h21,800–32,80068 / 68
COP at 5°F / −15°C1.8–2.2668 / 68
Equipment / loop typeHP - Split System68 / 68
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)68 / 68
Compressor stagingContinuously variable68 / 68
Connected capabilityNo68 / 68

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]48BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21749315218.007.80220001.82EPA 4470105 →
7AH2AE48PX-**AHRI reference: 21749315818.008.20234002.06EPA 4470107 →
7AH1AE48PX-**AHRI reference: 21749315918.007.80234002.06EPA 4470124 →
7E[C,U]50/60CX-**+TDR+ furnace: 80G1UH090BE16*AHRI reference: 21749316818.008.20234001.88EPA 4470157 →
7E[C,U]48CX-**+TDR+ furnace: 80G1UH090BE16*AHRI reference: 21749317218.007.80220001.82EPA 4470180 →
7EH51CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21749317818.008.20288001.92EPA 4470200 →
7ED60DX-**+TDR+ furnace: 97G2DF110CE20*AHRI reference: 21749319717.508.50298001.92EPA 4469549 →
7E[C,U]48CX-**+TDR+ furnace: 80G1UH100CE20X*AHRI reference: 21749313017.507.80224001.80EPA 4470066 →
7E[C,U]50/60CX-**+TDR+ furnace: 80G1UH100CE20X*AHRI reference: 21749311517.508.20238001.84EPA 4470075 →
7E[C,U]50/60CX-**+TDR+ furnace: 80G2UH110CE20*AHRI reference: 21749311817.508.20234001.88EPA 4470079 →
7E[C,U]50/60CX-**+TDR+ furnace: 80G2UH110CE20L*AHRI reference: 21749311917.508.20234001.88EPA 4470080 →
7E[C,U]50/60CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21749312417.508.20234001.88EPA 4470085 →
7E[C,U]50/60CX-**+TDR+ furnace: 92G1UH110CE20*AHRI reference: 21749312517.508.20236001.86EPA 4470086 →
7E[C,U]50/60CX-**+TDR+ furnace: 97G2UH110CV20*AHRI reference: 21749312817.508.00236001.88EPA 4470090 →
7EH48CX-**+TDR+ furnace: 80G1UH090CE20*AHRI reference: 21749314517.507.80238001.80EPA 4470098 →
7EH48CX-**+TDR+ furnace: 80G1UH110CE20*AHRI reference: 21749314617.507.80236001.80EPA 4470099 →
7EH48CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21749314717.507.80236001.80EPA 4470100 →
7AH2AE60PX-**AHRI reference: 21749316117.509.00328002.24EPA 4470129 →
7EH51CX-**+TDR+ furnace: 80G1UH110CE20*AHRI reference: 21749318217.508.20290001.90EPA 4470164 →
7EH51CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21749318317.508.20290001.90EPA 4470168 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.