Breeze33 / AIR-SOURCE HEAT PUMP

7HP19V36P-**A

7HP19V Series · source records, page 4

133 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,200BTU/h

Each efficiency range summarizes published EPA records for 7HP19V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 133 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20133 / 133
EER2 · BTU/Wh11–13133 / 133
HSPF2 · BTU/Wh7.8–8.5133 / 133
Cooling capacity · BTU/h21,600–35,200133 / 133
Heating capacity at 47°F / 8.3°C · BTU/h22,800–36,000133 / 133
Heating capacity at 17°F / −8.3°C · BTU/h14,100–21,600133 / 133
Heating capacity at 5°F / −15°C · BTU/h13,600–17,700133 / 133
COP at 5°F / −15°C1.48–2.2133 / 133
Equipment / loop typeHP - Split System133 / 133
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)133 / 133
Compressor stagingContinuously variable133 / 133
Connected capabilityNo133 / 133

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7AH2AV36PXC**AHRI reference: 21749307318.008.40177002.20EPA 4469967
7E[C,U]36BX-**+TDR+ furnace: 80G1UH070BE12*AHRI reference: 21749307818.008.20149001.92EPA 4469969
7E[C,U]36BX-**+TDR+ furnace: 80G1UH070BE12L*AHRI reference: 21749307918.008.20149001.92EPA 4469973
7E[C,U]36BX-**+TDR+ furnace: 92G1UH045BE12*AHRI reference: 21749308218.008.20149001.92EPA 4469981
7E[C,U]36BX-**+TDR+ furnace: 96G1UH070BE12*AHRI reference: 21749308418.008.20150001.92EPA 4469991
7E[C,U]36BX-**+TDR+ furnace: 97G2UH070BE12*AHRI reference: 21749308618.008.20150001.90EPA 4470001
7E[C,U]36BX-**+TDR+ furnace: 97G2UH045BE12*AHRI reference: 21749308718.008.20148001.92EPA 4470005
7E[C,U]36AX-**+TDR+ furnace: 80G1UH070AE12*AHRI reference: 21749309518.008.20150001.90EPA 4470046
7E[C,U]36AX-**+TDR+ furnace: 80G1UH070AE12L*AHRI reference: 21749309618.008.20149001.92EPA 4470051
7E[C,U]24BX-**+TDR+ furnace: 95G1UH040BE12X*AHRI reference: 21749316018.008.50167002.02EPA 4470128
7E[C,U]30BX-**+TDR+ furnace: 96G1UH045BE12*AHRI reference: 21749323518.008.20142001.86EPA 4470226
7E[C,U]30BX-**+TDR+ furnace: 96G1UH070BE12*AHRI reference: 21749323618.008.20140001.88EPA 4470234
7E[C,U]24BX-**+TDR+ furnace: 95G1UH060BE12X*AHRI reference: 21749320118.008.50167002.02EPA 4470277
7E[C,U]30BX-**+TDR+ furnace: 97G2UH070BE12*AHRI reference: 21749324918.008.20141001.88EPA 4470281
7E[C,U]30BX-**+TDR+ furnace: 95G1UH040BE12X*AHRI reference: 21749322518.008.20142001.86EPA 4470285
7E[C,U]30BX-**+TDR+ furnace: 95G1UH060BE12X*AHRI reference: 21749322618.008.20141001.86EPA 4470289
7E[C,U]30BX-**+TDR+ furnace: 97G2UH045BE12*AHRI reference: 21749325118.008.20141001.88EPA 4470313
7E[C,U]30AX-**+TDR+ furnace: 80G1UH070AE12*AHRI reference: 21749326318.008.20138001.88EPA 4470351
7EH30BX-**+TDR+ furnace: 92G1UH045BE12*AHRI reference: 21749324517.508.50152001.88EPA 4469611
7EH30BX-**+TDR+ furnace: 92G1UH070BE12*AHRI reference: 21749324717.508.50151001.90EPA 4469615

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →