Breeze33 / AIR-SOURCE HEAT PUMP

7HP14F18P-**A

7HP14F Series · source records, page 2

44 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 44 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.544 / 44
EER2 · BTU/Wh13–14.244 / 44
HSPF2 · BTU/Wh7.844 / 44
Cooling capacity · BTU/h18,00044 / 44
Heating capacity at 47°F / 8.3°C · BTU/h17,500–18,00044 / 44
Heating capacity at 17°F / −8.3°C · BTU/h10,500–11,20044 / 44
Heating capacity at 5°F / −15°C · BTU/h7,900–8,50044 / 44
COP at 5°F / −15°C1.86–2.0644 / 44
Equipment / loop typeHP - Split System44 / 44
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)44 / 44
Compressor stagingSingle stage44 / 44
Connected capabilityNo44 / 44

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7AH1AV24PX-**AHRI reference: 21579225916.007.8084001.98EPA 3653426
7AH2AV24PXC**AHRI reference: 21579226016.007.8083002.06EPA 3653427
7EH30AX-**+TDR+ furnace: 80G2UH045AE12*AHRI reference: 21579231316.007.8083001.96EPA 3653458
7EH24BX-**+TDR+ furnace: 95G1UH060BE12X*AHRI reference: 21579230016.007.8083001.96EPA 3653475
7EH24BX-**+TDR+ furnace: 80G2UH090BE12*AHRI reference: 21579230116.007.8083001.96EPA 3653480
7EH24AX-**+TDR+ furnace: 80G2UH070AE12L*AHRI reference: 21579229416.007.8080001.96EPA 3653600
7EH24BX-**+TDR+ furnace: 97G2UH045BV12*AHRI reference: 21649875116.007.8082001.94EPA 3847480
7EH24AX-**+TDR+ furnace: 80G2UH070AV12*AHRI reference: 21677913416.007.8080001.98EPA 3992820
7EH24BX-**+TDR+ furnace: 80G2UH090BV16*AHRI reference: 21677913516.007.8082001.94EPA 3992821
7EH24BX-**+TDR+ furnace: 97G2UH070BV12*AHRI reference: 21677913716.007.8082001.96EPA 3992823
7EH24AX-**+TDR+ furnace: 80G1UH040AE12X*AHRI reference: 21579229015.507.8080001.94EPA 3653364
7EH24AX-**+TDR+ furnace: 80G1UH060AE12X*AHRI reference: 21579229115.507.8080001.94EPA 3653365
7EH24AX-**+TDR+ furnace: 80G2UH045AE12*AHRI reference: 21579229215.507.8081001.92EPA 3653366
7ED30/36BX-**+TDR+ furnace: 92G1DF070BE12*AHRI reference: 21579233715.507.8084001.94EPA 3653379
7ED30/36BX-**+TDR+ furnace: 96G1DF045BE12*AHRI reference: 21579233815.507.8084001.92EPA 3653380
7EH24BX-**+TDR+ furnace: 92G1UH030BE12*AHRI reference: 21579230615.507.8084001.94EPA 3653390
7AH2AE18PX-**AHRI reference: 21579226115.507.8083002.04EPA 3653428
7ED30/36BX-**+TDR+ furnace: 92G1DF045BE12*AHRI reference: 21579233615.507.8084001.92EPA 3653472
7EH24BX-**+TDR+ furnace: 97G2UH030BE08*AHRI reference: 21677913615.507.8083001.94EPA 3992822
7AH1AC24PX-**AHRI reference: 21579225715.207.8084001.98EPA 3653424

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.