Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 8

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,000–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8249 / 249
EER2 · BTU/Wh12.2–14249 / 249
HSPF2 · BTU/Wh7.8–8.7249 / 249
Cooling capacity · BTU/h35,000–36,000249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800249 / 249
Heating capacity at 5°F / −15°C · BTU/h16,800–19,200249 / 249
COP at 5°F / −15°C2.06–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC36AX-0*+TDR+ furnace: 80G1UH045AE12AHRI reference: 21470890716.007.80170002.12EPA 3494377
7EH42BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21470880116.008.10184002.24EPA 3494405
7EH42BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21470880216.008.10184002.24EPA 3494406
7EC36AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21470890416.007.80174002.14EPA 3494455
7EH42CX-0*+TDR+ furnace: 80G2UH110CV20AHRI reference: 21470883216.008.00182002.18EPA 3494462
7EH51CX-0*+TDR+ furnace: 80G1UH100CE20XAHRI reference: 21470885516.008.00176002.18EPA 3494485
7EH51CX-0*+TDR+ furnace: 95G1UH080CE16XAHRI reference: 21470885616.007.80176002.18EPA 3494486
7EH51CX-0*+TDR+ furnace: 97G2UH090CV20AHRI reference: 21470886316.008.10178002.16EPA 3494503
7EC36BX-0*+TDR+ furnace: 92G1UH070BE12AHRI reference: 21470892916.007.80171002.14EPA 3494547
7EH42BX-0*+TDR+ furnace: 92G1UH070BE12AHRI reference: 21470880716.008.10183002.22EPA 3494603
7EH42BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 21470881016.008.10186002.26EPA 3494607
7EH42CX-0*+TDR+ furnace: 80G1UH100CE20XAHRI reference: 21470881216.008.00182002.18EPA 3494609
7EC50/60CX-0*+TDR+ furnace: 95G1UH100CE20XAHRI reference: 21470895716.007.80172002.12EPA 3494615
7EC50/60CX-0*+TDR+ furnace: 97G2UH090CE16AHRI reference: 21470896116.007.80171002.12EPA 3494660
7EC50/60CX-0*+TDR+ furnace: 97G2UH090CV12AHRI reference: 21470896216.007.80173002.12EPA 3494662
7EC50/60CX-0*+TDR+ furnace: 97G2UH110CE20AHRI reference: 21470896416.007.80172002.10EPA 3494664
7EC50/60CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 21470896516.007.80174002.12EPA 3494666
7EC36BX-0*+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21470891316.007.80171002.12EPA 3494712
7EC36BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21470891516.007.80171002.12EPA 3494717
7EC36BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21470891916.007.80171002.14EPA 3494720

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →