Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 6

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,000–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8249 / 249
EER2 · BTU/Wh12.2–14249 / 249
HSPF2 · BTU/Wh7.8–8.7249 / 249
Cooling capacity · BTU/h35,000–36,000249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800249 / 249
Heating capacity at 5°F / −15°C · BTU/h16,800–19,200249 / 249
COP at 5°F / −15°C2.06–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC50/60CX-0*+TDR+ furnace: 96G1UH110CE20AHRI reference: 21470897416.207.80172002.12EPA 3494852
7EH42CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 21470882216.208.10182002.20EPA 3543583
7EH51CX-0*+TDR+ furnace: 96G1UH090CE16AHRI reference: 21470887316.208.00175002.18EPA 3543617
7EH51CX-0*+TDR+ furnace: 92G1UH090CE16AHRI reference: 21470887016.207.80173002.16EPA 3543621
7ED48CX-0*+TDR+ furnace: 96G1DF110CE20AHRI reference: 21470890016.208.70189002.34EPA 3543642
7ED48CX-0*+TDR+ furnace: 96G1DF090CE16AHRI reference: 21470889916.208.70191002.34EPA 3543643
7ED48CX-0*+TDR+ furnace: 92G1DF090CE16AHRI reference: 21470889816.208.70191002.32EPA 3543644
7EH42BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21470879616.208.10183002.26EPA 3543671
7EH42BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21470879516.208.10183002.26EPA 3543672
7EH42BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21470879416.208.10185002.26EPA 3543673
7ED30/36CX-0*+TDR+ furnace: 80G1DF110CE20AHRI reference: 21470888816.208.10184002.16EPA 3543687
7EH48BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 21470884716.208.00172002.24EPA 3543724
7EH48BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21470884616.208.00172002.24EPA 3543725
7AH1AV42PX-0*AHRI reference: 21486539116.208.10174002.22EPA 3553852
EAC4X50/60C+TDR+ furnace: 92G1UH090CE12AHRI reference: 21331563416.007.80172002.10EPA 2840649
EAC4X36A+TDR+ furnace: 80G1UH045AE12AHRI reference: 21331561316.007.80170002.12EPA 2840669
EAC4X36A+TDR+ furnace: 80G1UH070AE12AHRI reference: 21331561516.007.80172002.12EPA 2840671
EAC4X36A+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21331561616.007.80172002.12EPA 2840672
EAH1P48B*+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21331567516.007.80172002.20EPA 2840674
EA(C;U)1P50/60C+TDR+TXV+ furnace: 92G1UH090CE12AHRI reference: 21331560116.007.80172002.10EPA 2840753

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →