Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 3

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,000–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8249 / 249
EER2 · BTU/Wh12.2–14249 / 249
HSPF2 · BTU/Wh7.8–8.7249 / 249
Cooling capacity · BTU/h35,000–36,000249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800249 / 249
Heating capacity at 5°F / −15°C · BTU/h16,800–19,200249 / 249
COP at 5°F / −15°C2.06–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH42CX-0*+TDR+ furnace: 97G2UH090CE16AHRI reference: 21470881816.408.00179002.22EPA 3494376
7EH42BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21470880316.408.10183002.28EPA 3494407
7EH42BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 21470880416.408.10183002.28EPA 3494408
7EH51CX-0*+TDR+ furnace: 80G1UH110CE20LAHRI reference: 21470886816.408.10174002.18EPA 3494506
7EH51CX-0*+TDR+ furnace: 80G1UH110CE20AHRI reference: 21470886716.408.10174002.18EPA 3494507
7EC50/60CX-0*+TDR+ furnace: 80G2UH110CE16AHRI reference: 21470895816.407.80170002.12EPA 3494638
7EC50/60CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21470895916.407.80171002.16EPA 3494642
7EC50/60CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21470896016.407.80171002.16EPA 3494646
7EC50/60CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21470896616.407.80170002.12EPA 3494667
7EC36BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21470891616.407.80170002.14EPA 3494716
7EC36BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21470891716.407.80170002.14EPA 3494718
7EC36BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21470891816.407.80170002.14EPA 3494719
7EC48CX-0*+TDR+ furnace: 92G1UH090CE12AHRI reference: 21470894716.407.80170002.14EPA 3494725
7EC48CX-0*+TDR+ furnace: 97G2UH090CE16AHRI reference: 21470894416.408.00171002.12EPA 3494757
7EH51CX-0*+TDR+ furnace: 96G1UH110CE20AHRI reference: 21470887416.408.00175002.22EPA 3543616
7EH51CX-0*+TDR+ furnace: 92G1UH110CE16AHRI reference: 21470887116.407.80174002.18EPA 3543618
7EH51CX-0*+TDR+ furnace: 92G1UH110CE20AHRI reference: 21470887216.408.00173002.20EPA 3543619
EAC4X50/60C+TDR+ furnace: 80G1UH110CE20AHRI reference: 21331563316.207.80173002.12EPA 2840648
EAC4X36B+TDR+ furnace: 80G1UH070BE12AHRI reference: 21331561816.207.80172002.14EPA 2840673
BCE5V42M*4XAHRI reference: 21331557816.208.10174002.22EPA 2840741