Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 9

198 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 198 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2198 / 198
EER2 · BTU/Wh12.2–13.5198 / 198
HSPF2 · BTU/Wh7.8–8.6198 / 198
Cooling capacity · BTU/h28,200–30,600198 / 198
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000198 / 198
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600198 / 198
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400198 / 198
COP at 5°F / −15°C1.96–2.36198 / 198
Equipment / loop typeHP - Split System198 / 198
Refrigerant / source-reported GWPR-410A (GWP:2088)198 / 198
Compressor stagingSingle stage198 / 198
Connected capabilityNo198 / 198

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH36CX-0*+TDR+ furnace: 92G1UH090CE16AHRI reference: 21470871015.608.30146002.24EPA 3543594
7EC30BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 21470875715.608.10145002.18EPA 3543682
7EC30BX-0*+TDR+ furnace: 92G1UH070BE12AHRI reference: 21470875315.608.00144002.20EPA 3543686
7EC30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21470874615.608.00145002.18EPA 3543707
7EC30BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21470874315.607.80143002.20EPA 3543709
7EC30BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21470875115.608.00143002.20EPA 3543712
7EC36BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21470877115.608.00146002.26EPA 3543728
7EC36BX-0*+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21470877015.608.10146002.24EPA 3543729
7AH2AE36PX-0*AHRI reference: 21486541415.508.50149002.36EPA 3553786
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21331546715.407.80143002.18EPA 2840730
EAC4X30B+TDR+ furnace: 96G1UH030BE08AHRI reference: 21331550415.407.80144002.20EPA 2840773
EAC4X30B+TDR+ furnace: 96G1UH045BE12AHRI reference: 21331550515.407.80143002.18EPA 2840774
EAC4X30B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21331550615.407.80143002.18EPA 2840775
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21331546815.407.80143002.18EPA 2840829
BCE5C36M*4XAHRI reference: 21331545115.408.10136002.14EPA 2840875
BCE5V30M*4XAHRI reference: 21331545315.408.10139002.16EPA 2840876
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21331546615.407.80144002.20EPA 2840947
EAD4X-42B+TDR+ furnace: 96G1DF045BE12AHRI reference: 21331553515.408.60154002.30EPA 2841162
7EC30BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21470874415.408.00145002.16EPA 3491734
7ED42BX-0*+TDR+ furnace: 96G1DF045BE12AHRI reference: 21470872515.408.60154002.30EPA 3494324