Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 10

198 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 198 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2198 / 198
EER2 · BTU/Wh12.2–13.5198 / 198
HSPF2 · BTU/Wh7.8–8.6198 / 198
Cooling capacity · BTU/h28,200–30,600198 / 198
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000198 / 198
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600198 / 198
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400198 / 198
COP at 5°F / −15°C1.96–2.36198 / 198
Equipment / loop typeHP - Split System198 / 198
Refrigerant / source-reported GWPR-410A (GWP:2088)198 / 198
Compressor stagingSingle stage198 / 198
Connected capabilityNo198 / 198

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21470873815.407.80143002.18EPA 3494365
7EH36CX-0*+TDR+ furnace: 80G1UH100CE20XAHRI reference: 21470869515.408.30149002.22EPA 3494434
7EH36CX-0*+TDR+ furnace: 95G1UH100CE20XAHRI reference: 21470869715.408.50148002.24EPA 3494436
7EH36CX-0*+TDR+ furnace: 95G1UH080CE16XAHRI reference: 21470869615.408.30145002.22EPA 3494437
7EC30BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 21470875615.407.80143002.18EPA 3543683
7EC30BX-0*+TDR+ furnace: 96G1UH045BE12AHRI reference: 21470875515.407.80143002.18EPA 3543684
7EC30BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21470875415.407.80144002.20EPA 3543685
7EC30BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21470874515.407.80144002.14EPA 3543708
7AH1AV30PX-0*AHRI reference: 21486535315.408.10139002.16EPA 3553844
7AH1AC36PX-0*AHRI reference: 21486538315.408.10136002.14EPA 3553940
EAC4X30B+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21331549915.208.00147002.16EPA 2840766
EA(C;U)1P30B+TDR+TXV+ furnace: 80G1UH080BE16XAHRI reference: 21331546115.208.00147002.16EPA 2840948
EAH1P30A*+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21331554115.207.80141001.96EPA 2840969
EAH1P30A*+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21331554315.207.80141001.96EPA 2840970
7EH36CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 21470870515.208.50152002.22EPA 3491787
7EC30BX-0*+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21470873715.208.00147002.16EPA 3494363
7EH30AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21470866415.207.80141001.96EPA 3543715
7EH30AX-0*+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21470866315.207.80141001.96EPA 3543716

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →