4HP17L30P-**A
4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 10
198 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 198 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.2 | 198 / 198 |
| EER2 · BTU/Wh | 12.2–13.5 | 198 / 198 |
| HSPF2 · BTU/Wh | 7.8–8.6 | 198 / 198 |
| Cooling capacity · BTU/h | 28,200–30,600 | 198 / 198 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 26,600–30,000 | 198 / 198 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,400–19,600 | 198 / 198 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,200–15,400 | 198 / 198 |
| COP at 5°F / −15°C | 1.96–2.36 | 198 / 198 |
| Equipment / loop type | HP - Split System | 198 / 198 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 198 / 198 |
| Compressor staging | Single stage | 198 / 198 |
| Connected capability | No | 198 / 198 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EC30BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 214708738 | 15.40 | 7.80 | 14300 | 2.18 | EPA 3494365 → |
7EH36CX-0*+TDR+ furnace: 80G1UH100CE20XAHRI reference: 214708695 | 15.40 | 8.30 | 14900 | 2.22 | EPA 3494434 → |
7EH36CX-0*+TDR+ furnace: 95G1UH100CE20XAHRI reference: 214708697 | 15.40 | 8.50 | 14800 | 2.24 | EPA 3494436 → |
7EH36CX-0*+TDR+ furnace: 95G1UH080CE16XAHRI reference: 214708696 | 15.40 | 8.30 | 14500 | 2.22 | EPA 3494437 → |
7EC30BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 214708756 | 15.40 | 7.80 | 14300 | 2.18 | EPA 3543683 → |
7EC30BX-0*+TDR+ furnace: 96G1UH045BE12AHRI reference: 214708755 | 15.40 | 7.80 | 14300 | 2.18 | EPA 3543684 → |
7EC30BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 214708754 | 15.40 | 7.80 | 14400 | 2.20 | EPA 3543685 → |
7EC30BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 214708745 | 15.40 | 7.80 | 14400 | 2.14 | EPA 3543708 → |
7AH1AV30PX-0*AHRI reference: 214865353 | 15.40 | 8.10 | 13900 | 2.16 | EPA 3553844 → |
7AH1AC36PX-0*AHRI reference: 214865383 | 15.40 | 8.10 | 13600 | 2.14 | EPA 3553940 → |
EAC4X30B+TDR+ furnace: 80G1UH080BE16XAHRI reference: 213315499 | 15.20 | 8.00 | 14700 | 2.16 | EPA 2840766 → |
EA(C;U)1P30B+TDR+TXV+ furnace: 80G1UH080BE16XAHRI reference: 213315461 | 15.20 | 8.00 | 14700 | 2.16 | EPA 2840948 → |
EAH1P30A*+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 213315541 | 15.20 | 7.80 | 14100 | 1.96 | EPA 2840969 → |
EAH1P30A*+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 213315543 | 15.20 | 7.80 | 14100 | 1.96 | EPA 2840970 → |
7EH36CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 214708705 | 15.20 | 8.50 | 15200 | 2.22 | EPA 3491787 → |
7EC30BX-0*+TDR+ furnace: 80G1UH080BE16XAHRI reference: 214708737 | 15.20 | 8.00 | 14700 | 2.16 | EPA 3494363 → |
7EH30AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 214708664 | 15.20 | 7.80 | 14100 | 1.96 | EPA 3543715 → |
7EH30AX-0*+TDR+ furnace: 80G1UH040AE12XAHRI reference: 214708663 | 15.20 | 7.80 | 14100 | 1.96 | EPA 3543716 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →