Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 8

199 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 199 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17199 / 199
EER2 · BTU/Wh12.5–14199 / 199
HSPF2 · BTU/Wh7.8–8.2199 / 199
Cooling capacity · BTU/h22,400–24,000199 / 199
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600199 / 199
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700199 / 199
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500199 / 199
COP at 5°F / −15°C2–2.16199 / 199
Equipment / loop typeHP - Split System199 / 199
Refrigerant / source-reported GWPR-410A (GWP:2088)199 / 199
Compressor stagingSingle stage199 / 199
Connected capabilityNo199 / 199

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 21470866216.007.80104002.00EPA 3543717 →
7AH2AE30PX-0*AHRI reference: 21486541216.008.20108002.16EPA 3553785 →
7AH1AE24PX-0*AHRI reference: 21486543016.007.80104002.08EPA 3553790 →
7AH1AE30PX-0*AHRI reference: 21486543316.008.10108002.06EPA 3553791 →
7AH1AV30PX-0*AHRI reference: 21486540916.008.10104002.06EPA 3553854 →
EAC4X30B+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21331539615.807.80106002.04EPA 2840653 →
EAC4X30B+TDR+ furnace: 92G1UH045BE12AHRI reference: 21331539915.807.80106002.00EPA 2840656 →
EAD4X-30/36B+TDR+ furnace: 92G1DF045BE12AHRI reference: 21331541115.808.20112002.06EPA 2840700 →
EAD4X-30/36B+TDR+ furnace: 92G1DF070BE12AHRI reference: 21331541215.808.20112002.06EPA 2840701 →
EA(C;U)1P24B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21331533915.807.80106002.00EPA 2840725 →
EA(C;U)1P24B+TDR+TXV+ furnace: 80G1UH080BE16XAHRI reference: 21331533615.807.80106002.02EPA 2840781 →
EAH1P24A*+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21331542415.807.80106002.04EPA 2840872 →
EAH1P24A*+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21331542615.807.80106002.04EPA 2840874 →
EA(C;U)1P30B+TDR+TXV+ furnace: 80G1UH080BE16XAHRI reference: 21331535615.807.80106002.04EPA 2840959 →
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21331535915.807.80106002.00EPA 2840962 →
EAC4X24B+TDR+ furnace: 92G1UH045BE12AHRI reference: 21331537915.807.80106002.00EPA 2841017 →
EAC4X24B+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21331537615.807.80106002.02EPA 2841160 →
BCE5V24M*4XAHRI reference: 21331532715.808.00108002.12EPA 2841170 →
7EC30BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21470865015.807.80106002.06EPA 3494386 →
7EC30AX-0*+TDR+ furnace: 80G2UH070AE12AHRI reference: 21470863415.807.80106002.04EPA 3494512 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →