Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 6

199 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 199 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17199 / 199
EER2 · BTU/Wh12.5–14199 / 199
HSPF2 · BTU/Wh7.8–8.2199 / 199
Cooling capacity · BTU/h22,400–24,000199 / 199
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600199 / 199
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700199 / 199
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500199 / 199
COP at 5°F / −15°C2–2.16199 / 199
Equipment / loop typeHP - Split System199 / 199
Refrigerant / source-reported GWPR-410A (GWP:2088)199 / 199
Compressor stagingSingle stage199 / 199
Connected capabilityNo199 / 199

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X24A+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21331537116.007.80106002.02EPA 2840760 →
EAH1P30B*+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21331544316.007.80108002.04EPA 2840809 →
EAH1P30B*+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21331544416.007.80108002.04EPA 2840810 →
EAC4X24A+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21331536916.007.80106002.02EPA 2840879 →
EA(C;U)1P24A+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21331533116.007.80106002.02EPA 2840902 →
BCE5V30M*4XAHRI reference: 21331532816.008.10104002.06EPA 2840955 →
EA(C;U)1P24A+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21331532916.007.80106002.02EPA 2840957 →
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21331536116.007.80102002.00EPA 2840964 →
EAC4X30A+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21331538916.007.80106002.04EPA 2840966 →
EAH1P30A*+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21331543016.008.10105002.10EPA 2840975 →
EAH1P30A*+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21331543216.008.10105002.10EPA 2840976 →
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21331534916.007.80106002.04EPA 2841012 →
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21331535116.007.80106002.04EPA 2841013 →
EAC4X24B+TDR+ furnace: 92G1UH070BE12AHRI reference: 21331538016.007.80106002.06EPA 2841018 →
EAC4X30A+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21331539116.007.80106002.04EPA 2841171 →
7EH24AX-0*+TDR+ furnace: 80G2UH070AE12LAHRI reference: 21470854216.007.80105002.04EPA 3491727 →
7ED30/36CX-0*+TDR+ furnace: 97G2DF090CE16AHRI reference: 21470859116.008.20113002.10EPA 3494326 →
7EH30AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21470855016.008.10105002.10EPA 3494345 →
7EH30AX-0*+TDR+ furnace: 80G2UH070AE12AHRI reference: 21470855216.008.10108002.12EPA 3494346 →
7EH30AX-0*+TDR+ furnace: 80G2UH070AE12LAHRI reference: 21470855316.008.10108002.12EPA 3494347 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →