Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L18P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 6

204 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 204 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8204 / 204
EER2 · BTU/Wh12.2–14204 / 204
HSPF2 · BTU/Wh7.8–8.5204 / 204
Cooling capacity · BTU/h18,000204 / 204
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000204 / 204
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100204 / 204
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700204 / 204
COP at 5°F / −15°C1.9–2.16204 / 204
Equipment / loop typeHP - Split System204 / 204
Refrigerant / source-reported GWPR-410A (GWP:2088)204 / 204
Compressor stagingSingle stage204 / 204
Connected capabilityNo204 / 204

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH24AX-0*+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21470841416.408.0080002.04EPA 3543738
7ED30/36BX-0*+TDR+ furnace: 96G1DF045BE12AHRI reference: 21470846616.408.3087002.10EPA 3543740
EAC4X24B+TDR+ furnace: 92G1UH070BE12AHRI reference: 21331524916.208.1082002.10EPA 2840633
EAC4X24A+TDR+ furnace: 80G1UH045AE12AHRI reference: 21331524016.208.0082002.08EPA 2840685
EAD4X-30/36B+TDR+ furnace: 96G1DF070BE16AHRI reference: 21331528116.208.4090002.08EPA 2840723
EA(C;U)1P24A+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21331520216.208.0082002.08EPA 2840749
EA(C;U)1P24B+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21331521116.208.1082002.10EPA 2840815
7EC24AX-0*+TDR+ furnace: 80G1UH045AE12LAHRI reference: 21470847916.208.0082002.08EPA 3491817
7EC24AX-0*+TDR+ furnace: 80G1UH045AE12AHRI reference: 21470847816.208.0082002.08EPA 3491818
7EC24BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21470848916.208.0082002.06EPA 3494491
7EC24BX-0*+TDR+ furnace: 92G1UH070BE12AHRI reference: 21470849916.208.1082002.10EPA 3543631
7ED30/36BX-0*+TDR+ furnace: 96G1DF070BE16AHRI reference: 21470846716.208.4090002.08EPA 3543741
EAC4X24B+TDR+ furnace: 92G1UH030BE12AHRI reference: 21331524716.008.1084002.08EPA 2840631
EAC4X24B+TDR+ furnace: 92G1UH045BE12AHRI reference: 21331524816.008.0082002.06EPA 2840632
EAC4X30A+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21331525916.007.8075001.92EPA 2840652
EAD4X-30/36C+TDR+ furnace: 92G1DF090CE16AHRI reference: 21331528716.008.4093002.06EPA 2840697
EAD4X-30/36C+TDR+ furnace: 96G1DF090CE16AHRI reference: 21331528816.008.4093002.06EPA 2840698
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21331521916.007.8075001.92EPA 2840713
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21331522116.007.8075001.92EPA 2840714
EAD4X-30/36B+TDR+ furnace: 80G1DF070BE12AHRI reference: 21331527716.008.3087002.06EPA 2840719

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →