Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L18P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 3

204 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 204 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8204 / 204
EER2 · BTU/Wh12.2–14204 / 204
HSPF2 · BTU/Wh7.8–8.5204 / 204
Cooling capacity · BTU/h18,000204 / 204
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000204 / 204
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100204 / 204
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700204 / 204
COP at 5°F / −15°C1.9–2.16204 / 204
Equipment / loop typeHP - Split System204 / 204
Refrigerant / source-reported GWPR-410A (GWP:2088)204 / 204
Compressor stagingSingle stage204 / 204
Connected capabilityNo204 / 204

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P24A+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21331520516.408.0082002.10EPA 2840798
EA(C;U)1P24B+TDR+TXV+ furnace: 80G1UH070BE12AHRI reference: 21331520616.408.0082002.10EPA 2840799
EAH1P30B*+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21331531316.407.8078001.98EPA 2840828
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21331522916.407.8076001.98EPA 2840860
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21331522816.407.8079001.96EPA 2840861
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21331523216.407.8077001.98EPA 2840865
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21331523316.407.8077001.98EPA 2840866
EAC4X30B+TDR+ furnace: 92G1UH045BE12AHRI reference: 21331526716.407.8076001.98EPA 2840868
EAC4X24A+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21331524316.408.0082002.10EPA 2840870
EAC4X24B+TDR+ furnace: 80G1UH070BE12AHRI reference: 21331524416.408.0082002.10EPA 2840871
EAC4X30B+TDR+ furnace: 96G1UH045BE12AHRI reference: 21331527016.407.8077001.98EPA 2840891
EAC4X30B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21331527116.407.8077001.98EPA 2840892
EAH1P24B*+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21331530216.408.1082002.10EPA 2840899
EAH1P24A*+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21331529216.408.0080002.06EPA 2840928
EAH1P24A*+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21331529516.408.0080002.04EPA 2840930
EAH1P24B*+TDR+TXV+ furnace: 80G1UH070BE12AHRI reference: 21331529716.408.1082002.10EPA 2840953
EAH1P24A*+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21331529416.408.0080002.04EPA 2840954
EAH1P30B*+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21331531816.407.8077002.00EPA 2841004
EAH1P30B*+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21331531716.407.8077001.98EPA 2841007
EAH1P24B*+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21331530116.408.1082002.08EPA 2841161

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →