Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L18P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 10

204 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 204 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8204 / 204
EER2 · BTU/Wh12.2–14204 / 204
HSPF2 · BTU/Wh7.8–8.5204 / 204
Cooling capacity · BTU/h18,000204 / 204
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000204 / 204
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100204 / 204
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700204 / 204
COP at 5°F / −15°C1.9–2.16204 / 204
Equipment / loop typeHP - Split System204 / 204
Refrigerant / source-reported GWPR-410A (GWP:2088)204 / 204
Compressor stagingSingle stage204 / 204
Connected capabilityNo204 / 204

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P30B*+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21331531215.607.8080001.92EPA 2840827
EAH1P24B*+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21331530315.608.1084002.06EPA 2840898
7EH24BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21470843315.608.1084002.06EPA 3494398
7EH30BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21470844215.607.8080001.92EPA 3494430
7EH30BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21470844315.607.8080001.92EPA 3494432
7EH30BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 21470845115.607.8080001.92EPA 3543611
7EH30BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21470845015.607.8080001.92EPA 3543620
7EC24BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21470850015.608.0084002.06EPA 3543630
7AH1AV24PX-0*AHRI reference: 21486538015.608.1084002.12EPA 3553767
7AH2AE18PX-0*AHRI reference: 21486533615.508.1082002.16EPA 3553822
BCE5C24M*4XAHRI reference: 21331519715.408.1085002.10EPA 2840743
BCE5C24M*1P+TXVAHRI reference: 21331519615.408.1085002.10EPA 2841155
7ED30/36BX-0*+TDR+ furnace: 97G2DF070BV16AHRI reference: 21470846215.408.4097002.02EPA 3543650
7AH1AC24PX-0*AHRI reference: 21486537815.408.1085002.10EPA 3553766
EAC4X30B+TDR+ furnace: 80G1UH090BE16AHRI reference: 21331526515.207.8081001.94EPA 2840734
BCE5C18M*1P+TXVAHRI reference: 21331519515.208.0085002.02EPA 2840742
EA(C;U)1P30B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21331522715.207.8081001.94EPA 2840858
BCE5C18M*4XAHRI reference: 21361519915.208.0085002.02EPA 2842323
7EC30BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21470852815.207.8081001.94EPA 3494353
7EC30BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21470852115.207.8081001.90EPA 3494390

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.