BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L36P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 4

131 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,000–36,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 131 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8131 / 131
EER2 · BTU/Wh12.2–13.5131 / 131
HSPF2 · BTU/Wh7.8–8.7131 / 131
Cooling capacity · BTU/h35,000–36,000131 / 131
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000131 / 131
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800131 / 131
Heating capacity at 5°F / −15°C · BTU/h16,800–19,100131 / 131
COP at 5°F / −15°C2.08–2.34131 / 131
Equipment / loop typeHP - Split System131 / 131
Refrigerant / source-reported GWPR-410A (GWP:2088)131 / 131
Compressor stagingSingle stage131 / 131
Connected capabilityNo131 / 131

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC742HBT-0*+TDR+ furnace: BG802UH090BE16AHRI reference: 21471343716.208.10183002.26EPA 3487317
BC748CCT-0*+TDR+ furnace: BG802UH110CV20AHRI reference: 21471350916.208.00172002.10EPA 3487328
BC748DCT-0*+TDR+ furnace: BG96G1DF090CE16AHRI reference: 21471348216.208.70191002.34EPA 3487331
BC748DCT-0*+TDR+ furnace: BG96G1DF110CE20AHRI reference: 21471348316.208.70189002.34EPA 3487332
BC751HCT-0*+TDR+ furnace: BG921UH090CE16AHRI reference: 21471346716.207.80173002.16EPA 3487446
BC751HCT-0*+TDR+ furnace: BG961UH090CE16AHRI reference: 21471347016.208.00175002.18EPA 3487484
BC730/36DCT-0*+TDR+ furnace: BG80G1DF110CE20AHRI reference: 21471347716.208.10184002.16EPA 3487493
BC750/60CCT-0*+TDR+ furnace: BG801UH110CE20AHRI reference: 21471351216.207.80173002.12EPA 3487513
BC750/60CCT-0*+TDR+ furnace: BG921UH090CE16AHRI reference: 21471351416.207.80172002.14EPA 3487515
BC750/60CCT-0*+TDR+ furnace: BG921UH110CE16AHRI reference: 21471351516.207.80170002.12EPA 3487517
BC750/60CCT-0*+TDR+ furnace: BG961UH090CE16AHRI reference: 21471351716.207.80172002.12EPA 3487518
BC736CBT-0*+TDR+ furnace: BG801UH070BE12AHRI reference: 21471349216.207.80172002.14EPA 3487526
BC751HCT-0*+TDR+ furnace: BG921UH090CE12AHRI reference: 21471346616.207.80175002.16EPA 3491592
BAH7V42PT-0*AHRI reference: 21486615016.208.10174002.22EPA 3553926
BC1P36A+TDR+TXV+ furnace: BG802UH070AE12AHRI reference: 21032535516.007.80170002.12EPA 2455756
BC1P36A+TDR+TXV+ furnace: BG801UH045AE12AHRI reference: 21032529516.007.80170002.12EPA 2455769
BC4X36A+TDR+ furnace: BG802UH070AE12AHRI reference: 21044132616.007.80170002.12EPA 2456458
BC4X36B+TDR+ furnace: BG921UH070BE12AHRI reference: 21044133716.007.80171002.14EPA 2456489
BC4X36A+TDR+ furnace: BG801UH070AE12AHRI reference: 21044132816.007.80172002.12EPA 2456507
BC1P36B+TDR+TXV+ furnace: BG921UH070BE12AHRI reference: 21044131016.007.80171002.14EPA 2458554

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →