BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L36P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 3

131 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,000–36,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 131 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8131 / 131
EER2 · BTU/Wh12.2–13.5131 / 131
HSPF2 · BTU/Wh7.8–8.7131 / 131
Cooling capacity · BTU/h35,000–36,000131 / 131
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000131 / 131
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800131 / 131
Heating capacity at 5°F / −15°C · BTU/h16,800–19,100131 / 131
COP at 5°F / −15°C2.08–2.34131 / 131
Equipment / loop typeHP - Split System131 / 131
Refrigerant / source-reported GWPR-410A (GWP:2088)131 / 131
Compressor stagingSingle stage131 / 131
Connected capabilityNo131 / 131

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BE5V42MA4XAHRI reference: 21117442016.208.10174002.22EPA 2454741
BC1P36A+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21032531316.207.80172002.14EPA 2455340
BC4X36B+TDR+ furnace: BG802UH090BV16AHRI reference: 21044133916.207.80172002.14EPA 2456492
BC4X36B+TDR+ furnace: BG801UH070BE12AHRI reference: 21044133416.207.80172002.14EPA 2456511
BC1P36B+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21044131216.207.80172002.14EPA 2457095
BC1P36B+TDR+TXV+ furnace: BG801UH070BE12AHRI reference: 21044130716.207.80172002.14EPA 2458587
BC1P36A+TDR+TXV+ furnace: BG801UH070BE12AHRI reference: 21032530916.207.80172002.14EPA 2461128
BH1P48B*+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21173631416.208.00172002.20EPA 2463247
BH1P48B*+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21173641016.208.00172002.24EPA 2464478
BH1P51C*+TDR+TXV+ furnace: BG921UH090CE16AHRI reference: 21173673116.207.80173002.16EPA 2464904
BH1P51C*+TDR+TXV+ furnace: BG961UH090CE16AHRI reference: 21173677716.208.00175002.18EPA 2465344
BH1P48B*+TDR+TXV+ furnace: BG802UH090BE12AHRI reference: 21173629916.208.00174002.22EPA 2467964
BH1P51C*+TDR+TXV+ furnace: BG921UH090CE12AHRI reference: 21173671616.207.80175002.16EPA 2469285
BC748HBT-0*+TDR+ furnace: BG802UH090BE12AHRI reference: 21471345516.208.00174002.22EPA 3486981
BC748HBT-0*+TDR+ furnace: BG802UH090BE16AHRI reference: 21471345616.208.00172002.20EPA 3486985
BC748HBT-0*+TDR+ furnace: BG801UH090BE16AHRI reference: 21471345816.208.00172002.24EPA 3486991
BC742HCT-0*+TDR+ furnace: BG921UH090CE12AHRI reference: 21471344716.208.00181002.18EPA 3487253
BC750/60CCT-0*+TDR+ furnace: BG961UH110CE20AHRI reference: 21471351816.207.80172002.12EPA 3487304
BC742HBT-0*+TDR+ furnace: BG802UH090BE12AHRI reference: 21471343616.208.10185002.26EPA 3487313
BC736CBT-0*+TDR+ furnace: BG802UH090BV16AHRI reference: 21471349716.207.80172002.14EPA 3487316

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →